Breast cancer (Tokyo, Japan)

Feasibility and safety of intraoperative photodynamic diagnosis using 5-aminolevulinic acid in breast cancer surgery.

Haruru Kotani, Ayako Isogai, Akira Nakakami, Ayumi Kataoka, Akiyo Yoshimura, Masaya Hattori, Masataka Sawaki, Fumikata Hara,

Department of Breast Oncology, Aichi Cancer Center, 1-1 Kanokoden, Chikusa-ku, Nagoya, 464-8681, Japan. k.haruru@aichi-cc.jp. · Department of Breast Surgery, Nagoya City University Graduate School of Medicine, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan.

Observational · n=6

Key points

From the paper's conclusion
  • In this prospective pilot study, intraoperative 5-ALA-based PDD was feasible and safe in breast cancer specimens. The addition of fluorescence information may improve diagnostic performance compared with gross assessment alone, although the small number of evaluable cases means that these estimates are exploratory and hypothesis-generating rather than confirmatory. Further studies are warranted to determine its clinical utility in breast-conserving surgery.

Abstract

PURPOSE: Intraoperative margin assessment remains a clinical challenge in breast cancer surgery. We conducted a prospective pilot study to evaluate the feasibility, safety, and diagnostic performance of 5-aminolevulinic acid (5-ALA)-based photodynamic diagnosis (PDD) using a commercially available imaging system in Japan. METHODS: Patients with primary breast cancer scheduled for mastectomy and tumor size > 2 cm received oral 5-ALA (20 mg/kg) 2-4 h before surgery. Excised specimens were incised immediately after resection and examined under white light and blue-light PDD. Punch biopsies were obtained from areas classified by gross inspection and PDD findings. Pathology served as the reference standard. Primary endpoints were diagnostic odds ratio (DOR) and safety; secondary endpoints included sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: Ten patients received 5-ALA. PDD visualization was feasible in 6 cases when specimens were examined within 10 min after excision. A total of 33 punch biopsies were analyzed. Compared with gross inspection alone (sensitivity 84.6%, specificity 85.0%, DOR 31.2, 95% CI 4.5-217.6), the addition of PDD was associated with a sensitivity of 92.3%, specificity of 80.0%, and DOR of 48.0 (95% CI 4.7-486.3); the confidence intervals overlapped substantially. PDD identified a grossly occult tumor focus. No adverse events related to 5-ALA were observed. CONCLUSIONS: In this prospective pilot study, intraoperative 5-ALA-based PDD was feasible and safe in breast cancer specimens. The addition of fluorescence information may improve diagnostic performance compared with gross assessment alone, although the small number of evaluable cases means that these estimates are exploratory and hypothesis-generating rather than confirmatory. Further studies are warranted to determine its clinical utility in breast-conserving surgery.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers