Radiological physics and technology

Localisation and classification of preselected thyroid ultrasound nodules: cross-cohort performance of a public-dataset model with limited local data.

Ohta Yukino, Daniel Carrion, Ilona Lavender, Moshi Geso, Mohamed Badawy

Department of Clinical Radiology, Faculty of Health Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashi-Hiroshima City, 739-2695, Hiroshima, Japan. · Monash Radiology, Monash Health, Clayton, Melbourne, VIC, Australia. dcarrion87@gmail.com.

Observational

Key points

From the paper's conclusion
  • Under the training design evaluated, mixed public-plus-local training retained source-domain performance better than fine-tuning; these retrospective, exploratory findings do not establish clinical readiness.

Abstract

Public-dataset models are rarely characterised on local data. A YOLOv8m model trained on the fine-needle-aspiration-labelled public TN5000 thyroid ultrasound dataset was tested on two independent cohorts. Images were cropped to a preselected nodule. Mean average precision at intersection-over-union 0.5 (mAP@0.5) fell from 0.825 on TN5000 to 0.415 on the Stanford Artificial Intelligence in Medicine and Imaging (AIMI) cohort and 0.420 on the institutional cohort, indicating domain shift. Stepwise fine-tuning raised institutional mAP@0.5 to 0.630 (95% confidence interval, CI, 0.525-0.730) but degraded TN5000 performance to 0.323-0.421, indicating catastrophic forgetting; single-stage mixed retraining reached 0.611 (0.521-0.716) and 0.788-0.819 on TN5000 up to a 40% institutional proportion. Training each selected configuration three times gave standard deviations of 0.057 and 0.069, larger than any difference between adjacent fine-tuning sizes, and neither repeat of the 30% mixed model was separable from the baseline, so no configuration is identified as best. After multiplicity correction the only separable adjacent step was a decline, from 40% to 50% institutional data. Lesion-level detection exceeded 0.90 sensitivity at about one false positive per imaging study, but discrimination of the cytology-defined malignant class was weak (end-to-end area under the receiver operating characteristic curve 0.701, 95% CI 0.610-0.780), and its gain over the baseline did not survive multiplicity correction (adjusted p = 0.059). Positive predictive value was 0.19 to 0.24 at 10% prevalence. Under the training design evaluated, mixed public-plus-local training retained source-domain performance better than fine-tuning; these retrospective, exploratory findings do not establish clinical readiness.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers