Localisation and classification of preselected thyroid ultrasound nodules: cross-cohort performance of a public-dataset model with limited local data.
Ohta Yukino, Daniel Carrion, Ilona Lavender, Moshi Geso, Mohamed Badawy
Department of Clinical Radiology, Faculty of Health Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashi-Hiroshima City, 739-2695, Hiroshima, Japan. · Monash Radiology, Monash Health, Clayton, Melbourne, VIC, Australia. dcarrion87@gmail.com.
Key points
From the paper's conclusion- Under the training design evaluated, mixed public-plus-local training retained source-domain performance better than fine-tuning; these retrospective, exploratory findings do not establish clinical readiness.
Abstract
Public-dataset models are rarely characterised on local data. A YOLOv8m model trained on the fine-needle-aspiration-labelled public TN5000 thyroid ultrasound dataset was tested on two independent cohorts. Images were cropped to a preselected nodule. Mean average precision at intersection-over-union 0.5 (mAP@0.5) fell from 0.825 on TN5000 to 0.415 on the Stanford Artificial Intelligence in Medicine and Imaging (AIMI) cohort and 0.420 on the institutional cohort, indicating domain shift. Stepwise fine-tuning raised institutional mAP@0.5 to 0.630 (95% confidence interval, CI, 0.525-0.730) but degraded TN5000 performance to 0.323-0.421, indicating catastrophic forgetting; single-stage mixed retraining reached 0.611 (0.521-0.716) and 0.788-0.819 on TN5000 up to a 40% institutional proportion. Training each selected configuration three times gave standard deviations of 0.057 and 0.069, larger than any difference between adjacent fine-tuning sizes, and neither repeat of the 30% mixed model was separable from the baseline, so no configuration is identified as best. After multiplicity correction the only separable adjacent step was a decline, from 40% to 50% institutional data. Lesion-level detection exceeded 0.90 sensitivity at about one false positive per imaging study, but discrimination of the cytology-defined malignant class was weak (end-to-end area under the receiver operating characteristic curve 0.701, 95% CI 0.610-0.780), and its gain over the baseline did not survive multiplicity correction (adjusted p = 0.059). Positive predictive value was 0.19 to 0.24 at 10% prevalence. Under the training design evaluated, mixed public-plus-local training retained source-domain performance better than fine-tuning; these retrospective, exploratory findings do not establish clinical readiness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic Performance and Calibration of AI Models for Thyroid Ultrasound Malignancy Classification: From TN5000 to ThyroidXL.Journal of imaging informatics in medicine · 2026
- Comparative evaluation of thyroid nodule ultrasound segmentation modelsCancer Imaging · 2026
- Fine-tuned Medical Vision-Language Model (MedGemma 1.5 4B) with and without Structured Radiologist Descriptors versus EU-TIRADS for Malignancy Risk Stratification of Thyroid Nodules at Ultrasound: A Tunisian Multicenter Diagnostic Accuracy StudymedRxiv · 2026
- Application of LLM combined with knowledge base in improving C-TIRADS grading of thyroid nodules.Frontiers in endocrinology · 2026
- Deep-Learning Algorithm for Indeterminate Thyroid Nodules: Comparison and Combination with Molecular TestingarXiv · 2026
- Utilizing the transformer mechanism to predict cervical lymph node metastasis in patients with papillary thyroid carcinomaPLoS ONE · 2026