Neurocritical care

Correlation and Agreement Between Bispectral Index Monitoring and Quantitative EEG in Aneurysmal Subarachnoid Hemorrhage.

Marina S Cherchi, Miguel A Hernández-Hernández, Javier Hernández-Cabello, Enrique Montes-Figueroa, Patricia López-Gómez, Miguel Santibañez, José L Fernández-Torre

Department of Intensive Medicine, Marqués de Valdecilla University Hospital, Avda. Valdecilla n° 25, 39008, Santander, Cantabria, Spain. · Department of Intensive Medicine, Marqués de Valdecilla University Hospital, Avda. Valdecilla n° 25, 39008, Santander, Cantabria, Spain. miguelangel.hernandez@scsalud.es.

Key points

From the paper's conclusion
  • BIS-derived parameters, particularly BIS-tpw and BIS-sef, were associated with qEEG measures of spectral power and frequency in aSAH. In contrast, BIS-v showed weaker and less reliable relationships with qEEG metrics. BIS monitoring may provide complementary bedside electrophysiological trends when continuous EEG is unavailable but should not be considered interchangeable with qEEG.

Abstract

BACKGROUND: Delayed cerebral ischemia (DCI) is a major cause of poor outcome after aneurysmal subarachnoid hemorrhage (aSAH). Continuous EEG can predict DCI but is resource intensive. Processed EEG monitors such as the bispectral index (BIS) are simpler, yet their relationship with quantitative EEG (qEEG) parameters remains unclear. We evaluated the correlation and agreement between BIS and qEEG in aSAH. METHODS: Single-center prospective study of adults with aSAH who underwent two 30-min routine EEG recordings with simultaneous bilateral BIS monitoring (within 72 h of admission and on days 4-7). qEEG parameters were extracted from frontal channels adjacent to the BIS sensor and from full-montage EEG recordings. Prespecified comparisons included BIS total power (BIS-tpw), spectral edge frequency (BIS-sef), and BIS value (BIS-v) with corresponding qEEG measures. Correlation and agreement were assessed using correlation coefficients, intraclass correlation, concordance analysis, regression methods, and Bland-Altman approaches. Exploratory analyses evaluated the DCI interaction in BIS-qEEG associations and concordance for DCI detection. RESULTS: Sixty-four patients contributed 248 paired BIS-qEEG observations. Prespecified parameter pairs showed moderate-to-strong correlations (ρ > 0.6), particularly between BIS-tpw and qEEG power measures and between BIS-sef and qEEG-sef. Agreement analyses were fair to good for BIS-tpw and BIS-sef [absolute intraclass correlation coefficients (ICCs) up to ~0.75; consistency ICCs ≥ 0.80]. In contrast, BIS-v showed weak correlations, poor agreement, and substantial between-patient variability. Associations were strongest with frontal qEEG parameters, whereas correlations with full-montage qEEG measures were moderate. DCI was associated with consistent BIS-qEEG differences and fair-to-good concordance. CONCLUSIONS: BIS-derived parameters, particularly BIS-tpw and BIS-sef, were associated with qEEG measures of spectral power and frequency in aSAH. In contrast, BIS-v showed weaker and less reliable relationships with qEEG metrics. BIS monitoring may provide complementary bedside electrophysiological trends when continuous EEG is unavailable but should not be considered interchangeable with qEEG.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.