Microplastic Detection in the Ascending Aorta: An Exploratory Study Using Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC/MS).
Han Shen, Yucheng Hou, Yuqian Tang, Tan Liu, Zhiao Zhang, Haoyue Huang, Yihuan Chen, Zhenya Shen
Department of Cardiovascular Surgery of the First Affiliated Hospital & Institute for Cardiovascular Science, Soochow University, Suzhou, Jiangsu, China. · Department of Critical Care Medicine and Emergency, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Key points
From the paper's conclusion- A total of 16 ascending aortic samples (8 acute type A aortic dissection [AD] and 8 acute type B dissection with arch involvement but a non-dissected ascending aorta [ND]) were examined using pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) to screen 11 polymers.
Abstract
Microplastics (MPs) have emerged as significant environmental pollutants that have been detected in various human tissues. This pilot biomonitoring study explored polymer mass in dissected versus non-dissected ascending aortic tissue. A total of 16 ascending aortic samples (8 acute type A aortic dissection [AD] and 8 acute type B dissection with arch involvement but a non-dissected ascending aorta [ND]) were examined using pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) to screen 11 polymers. Both groups had aortic disease. Polymer-related signals were reported in all samples, with total mass estimates ranging from 1.92 to 155.58 µg/g tissue. The predominant reported polymer was polyamide 66 (PA66; 50.7%), followed by polyvinyl chloride (PVC; 40.5%) and polyethylene terephthalate (PET; 8.8%). AD tissues showed a 3.9-fold higher estimated polymer burden than ND tissues (74.51 ± 42.81 vs. 19.25 ± 16.48 µg/g, p = 0.0077). PET estimates were also higher in AD tissues (7.36 ± 6.44 vs. 0.89 ± 1.49 µg/g, p = 0.025), but PET identification was tentative and polymer-specific tests were exploratory. Total polymer mass correlated with ascending aortic diameter (Spearman's rho = 0.865, p < 0.001). The age- and group-adjusted association (coefficient 0.079 mm per µg/g; p = 0.0098) was sensitive to omission of one observation (p = 0.140). These findings describe a difference in estimated polymer burden between two diseased-tissue groups. Incomplete analytical validation and possible perioperative contamination limit interpretation; particle identity, tissue localization, vascular toxicity and causality were not established. Further analytical and multicenter validation is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microplastics detection in freshly harvested human brain tissues of northeast Chinese postmortem donors and their correlation with Alzheimer's disease- related pathological proteins.Neurotoxicology · 2026
- Polymer Types, Concentrations, and Analytical Methods for Microplastics and Nanoplastics in Human Blood.Toxics · 2026
- Analytical techniques for detecting micro- and nanoplastics in blood and vascular tissues: Strengths and limitationsKardiologia Polska · 2026
- Suspected Microplastic-like Particles in Human Gastric Autopsy Samples: An Exploratory Histopathological and Biochemical Study.Life (Basel, Switzerland) · 2026
- Undiseased and diseased abdominal aortas contain environmentally relevant micronanoplastics.JVS-vascular science · 2026
- Detection and Characterization of Multiple Microplastics in the Human RetinaEnvironmental Science & Technology Letters · 2025