Research on Quality Inspection of PBF-LB 022Cr17Ni12Mo2 Steel Using Laser Ultrasonic Testing Technology.

Borui Zhang, Xianwei Yin, Chipeng Li, Chaochao Chen, Wanhong Li, Qiyuan Li, Anmin Yin

原始摘要(英文原文)· Original abstract
In this study, laser powder bed fusion (PBF-LB) 022Cr17Ni12Mo2 steel plates with dimensions of 50 mm × 50 mm × 2 mm were fabricated using a laser power of 206 W, a scanning speed of 900 mm/s, a hatch spacing of 90 μm, a layer thickness of 30 μm, and an interlayer scanning rotation of 67°. The specimens were then subjected to solution treatment at 900-1100 °C for 30 min and at 950 °C for 30-120 min. Unlike previous ultrasonic studies on additively manufactured metals, which mainly focused on defect detection, elastic-constant characterization, or residual stress evaluation, this work investigates whether solution-treatment-induced changes in grain size and dislocation density can be quantitatively reflected by laser-ultrasonic attenuation and further correlated with yield strength. Laser ultrasonic nondestructive testing using a 1064 nm pulsed laser with a pulse width of 8 ns and a pulse energy of 500 mJ was combined with metallographic observation, EBSD characterization, XRD analysis, tensile testing, and microhardness measurement. The results show that the solution-treated samples retained a single-phase γ-austenitic structure, while microstructural recovery, weakening of PBF-LB-induced cellular substructures, and partial annihilation of cell-wall dislocations led to a reduction in KAM-derived dislocation density from 2.04 × 1014 m-2 to 1.45 × 1014 m-2 and a decrease in yield strength from 466.9 MPa to 407.4 MPa. Within the present dataset, the EBSD-equivalent grain size showed an apparent positive correlation with ultrasonic attenuation, while the KAM-derived dislocation density showed an empirical negative correlation with ultrasonic attenuation. However, ultrasonic attenuation should be interpreted as a combined microstructure-sensitive response rather than as a response controlled only by EBSD-equivalent grain size or dislocation density. Based on the empirical correlations among ultrasonic attenuation, EBSD-equivalent grain size, KAM-derived dislocation density, and yield strength, a preliminary attenuation-based calibration model was established for the present solution-treated samples. The model should be regarded as an in-sample empirical calibration within the present experimental range rather than a general Hall-Petch-based predictive model. The model showed good in-sample fitting performance, with (R2) values higher than 0.85 and a maximum in-sample fitting error of 3.85%. However, because the model was established and assessed using the same eight solution-treatment conditions, it should be regarded as a preliminary calibration model within the present experimental range rather than a general predictive model. This study demonstrates the potential of laser ultrasonic attenuation for non-contact evaluation of microstructural and mechanical-property variations in solution-treated PBF-LB 022Cr17Ni12Mo2 steel.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Research on Quality Inspection of PBF-LB 022Cr17Ni12Mo2 Steel Using Laser Ultrasonic Testing Technology. — 科研速览 Science Skim