General thoracic and cardiovascular surgery

Feasibility and outcomes of long-segment tracheal replacement with biological and engineered scaffolds.

Qiang Su, Daichen Liu, Ying Han

Department of Cardiology, The First Hospital of Jilin University, Changchun, 130021, China. · Department of Chemical Engineering, University of Waterloo, Waterloo, ON, N2L 3G5, Canada.

Computational · n=147

Key points

From the paper's conclusion
  • Anatomy should precede material choice when interpreting tracheal replacement. Autologous vascularized composites have the most mature experience for selected Type I-II reconstruction, whereas Type III-IV intrathoracic and distal/carinal replacement remains more technically hazardous. Cryopreserved aortic allografts provide the current clinical benchmark for biologic full-circumference replacement but require structured stent and bronchoscopic management. Tracheal allotransplantation and engineered or xenogenic constructs remain limited or investigational.

Abstract

OBJECTIVES: To synthesize adult long-segment tracheal replacement using a combined anatomical and graft-based framework and to compare clinically established and investigational strategies with emphasis on mortality, morbidity, airway function, and reintervention. METHODS: PubMed/MEDLINE, Embase, Scopus, Web of Science, the Cochrane Library, and China National Knowledge Infrastructure were searched from January 1, 2000, to June 30, 2026. Adult replacements were classified as Type I (upper/cervical), Type II (cervico-mediastinal), Type III (intrathoracic), or Type IV (distal trachea/carina) and by graft class. Forty-three reports comprising 147 extractable patients were synthesized descriptively. The overlapping 50-patient TRITON-01 registry was analyzed separately as the principal cryopreserved aortic-allograft benchmark. RESULTS: Among 147 patients, 72 were Type I, 33 Type II, 25 Type III, and 17 Type IV; 113 (76.9%) had malignant disease. Autologous vascularized tissue composites were used in 74 patients (50.3%) and cryopreserved aortic allografts in 52 (35.4%). Overall 30-day and 90-day mortality were 4.8% and 9.5%, respectively. Decannulation was achieved in 103/139 (74.1%); 25.2% required repeat endoscopic intervention and 19.0% developed recurrent stenosis. In the updated 50-patient TRITON-01 registry, 30-day mortality was 4%, major complications 30%, stent-related granuloma 52%, and stent removal 30%. Reliable Type I-IV-specific mortality rates could not be pooled because primary reports did not consistently cross-tabulate outcomes by anatomical level. CONCLUSIONS: Anatomy should precede material choice when interpreting tracheal replacement. Autologous vascularized composites have the most mature experience for selected Type I-II reconstruction, whereas Type III-IV intrathoracic and distal/carinal replacement remains more technically hazardous. Cryopreserved aortic allografts provide the current clinical benchmark for biologic full-circumference replacement but require structured stent and bronchoscopic management. Tracheal allotransplantation and engineered or xenogenic constructs remain limited or investigational.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Feasibility and outcomes of long-segment tracheal replacement with biological and engineered scaffolds — Science Skim