Sealing strength and application efficiency of the microbubble fibrin sealant technique: influence of PGA sheet type in an ex vivo porcine lung model.
Ryuji Nakamura, Katsuhiro Okuda, Shin Hosokawa, Eiji Nakatani, Takayuki Murase, Singo Inaguma, Kensuke Iguchi, Kensuke Chiba,
Department of Thoracic and Pediatric Surgery, Graduate School of Medical Sciences and Medical School, Nagoya City University, 1 Kawasumi, Mizuho-Cho, Mizuho-Ku, Nagoya, 467-8601, Japan. · Department of Thoracic and Pediatric Surgery, Graduate School of Medical Sciences and Medical School, Nagoya City University, 1 Kawasumi, Mizuho-Cho, Mizuho-Ku, Nagoya, 467-8601, Japan. kokuda@med.nagoya-cu.ac.jp.
Key points
From the paper's conclusion- The microbubble technique demonstrated sealing strength comparable to that of the conventional technique while reducing fibrin sealant runoff. However, sealing performance appeared to depend on the PGA sheet type.
Abstract
OBJECTIVE: We previously proposed the microbubble fibrin sealant application technique (microbubble technique) for the precise and efficient delivery of fibrinogen to air leak sites. However, its sealing strength and application efficiency are still unclear. This study aimed to assess the non-inferiority of the microbubble technique in sealing strength, the influence of polyglycolic acid (PGA) sheet type, and its effect on reducing fibrin sealant runoff. METHODS: Pleural defects were created in ex vivo porcine lungs. Fibrin sealant was applied using either the conventional or microbubble technique with two types of PGA sheets. Seal-breaking pressure was measured, and the non-inferiority of the microbubble technique was assessed. The interaction between the application technique and the PGA sheet type was analyzed. In addition, the fibrin sealant runoff was evaluated on an inclined lung surface. RESULTS: Using the Neoveil® PGA sheet, the microbubble technique demonstrated seal-breaking pressure not inferior to that of the conventional technique (40.2 ± 8.4 vs. 40.9 ± 6.0 cmH2O; mean difference - 0.72 cmH2O; one-sided 95% confidence interval - 3.62 to infinity). The Neoveil® nano NJ type PGA sheet improved sealing strength with the conventional technique, but reduced it with the microbubble technique. A significant interaction between the PGA sheet type and the application technique was observed (P < 0.001). Histological analysis supported these findings. The microbubble technique significantly reduced fibrin sealant runoff (P < 0.001). CONCLUSION: The microbubble technique demonstrated sealing strength comparable to that of the conventional technique while reducing fibrin sealant runoff. However, sealing performance appeared to depend on the PGA sheet type.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A pulmonary air leak model for integrated assessment of pulmonary sealant performance and tissue remodelingFrontiers in Medicine · 2026
- Polyglycolic Acid Reinforcement for Prevention of Postoperative Air Leak after Pulmonary Resection for Pulmonary Malignancy: A Systematic Review and Meta-Analysis.Journal of chest surgery · 2026
- Electrospun Core-Shell Bioadhesive Nanofiber Sheets Enable Durable Pulmonary Air Leak Sealing Under Wet and Dynamic Conditions.Advanced healthcare materials · 2026
- Preliminary Evaluation of the Local Tissue Response, Biocompatibility, and Dural Repair of sFilm-FS, a Novel Bioabsorbable Fibrin Sealant, in a Rabbit Dural Defect Model.International journal of toxicology · 2026
- An Injury-Conforming Dual-Layer Lung Sealant.ACS biomaterials science & engineering · 2026
- An Injectable Low-Swelling and Mechanically Robust Bioadhesive Sealant for Sutureless Watertight Dural Repair.Advanced healthcare materials · 2026