  • We searched PubMed, Scopus, Web of Science, and CENTRAL for clinical studies of 5G telerobotic orthopedic trauma or spine surgery, in which a surgeon at a different site controls a robotic arm over a 5G network.

Abstract

Fifth-generation (5G) mobile networks allow an expert surgeon to plan and control orthopedic robots in distant hospitals, but evidence on the performance and safety of this approach remains scattered across small studies. We aim to synthesize the technical feasibility, implant accuracy, perioperative efficiency, and safety of 5G telerobotic surgery for orthopedic trauma and spinal disorders. We searched PubMed, Scopus, Web of Science, and CENTRAL for clinical studies of 5G telerobotic orthopedic trauma or spine surgery, in which a surgeon at a different site controls a robotic arm over a 5G network. We pooled outcomes reported by at least three studies with random-effects standardized mean differences (SMD), generalized linear mixed models for proportions, or exact intervals for pooled counts. Five non-randomized studies from two Chinese expert centers (343 patients; 176 treated remotely) met the criteria. Compared with local robot-assisted surgery, 5G telerobotic surgery showed no significant difference in operative time (three studies, 316 patients; SMD - 0.12, 95% CI -0.61 to 0.36; I² = 0%) or blood loss (SMD - 0.23, 95% CI -0.72 to 0.26; I² = 0%); intervals were wide. Breach-free screw placement was 98.6% (213 of 216) for pelvic and acetabular screws and 86.7% (104 of 120) for pedicle screws graded Gertzbein-Robbins A (97.5% grade A or B); an exploratory overall estimate was 96.2% (95% CI 67.3% to 99.7%) with substantial heterogeneity. All 176 procedures in five studies reached completion as planned (95% CI 97.9% to 100%), without network failure (0 of 176; 95% CI 0% to 2.1%) or robot malfunction (0 of 150); no neurovascular injury occurred in 70 patients followed to day 5 or discharge or in 106 followed for 6 to 16 months, and no surgical-site infection in 106 patients (two studies). These findings are preliminary and show technical feasibility only. In five small non-randomized studies from two Chinese expert centers, 5G telerobotic orthopedic trauma and spine surgery was completed as planned in all reported procedures, pelvic screw accuracy was high, and no network or robot failures were reported. No statistically significant difference in operative time or blood loss versus local robot-assisted surgery was detected, but the intervals were wide, equivalence was not tested, and confounding and selection bias cannot be excluded. Short follow-up, sparse network data, and the expert-center setting preclude conclusions about equivalence, long-term safety, or generalizability; prospective multicenter comparative studies should precede wider adoption.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers