Estimating exposure thresholds for robotic surgical skill decay: a systematic review and quantitative threshold synthesis.
Igor Monsellato, Marco Palucci, Fabiana Marotta, Fabio Giannone, Marco Lodin, Gianluca Cassese
SCDU Chirurgia Generale, IRCCS AOU SS. Antonio e Biagio e Cesare Arrigo, Via Venezia 16, 15121, Alessandria, Italy. igor.monsellato@ospedale.al.it. · SCDU Chirurgia Generale, IRCCS AOU SS. Antonio e Biagio e Cesare Arrigo, Via Venezia 16, 15121, Alessandria, Italy.
Key points
From the paper's conclusion- We systematically reviewed PubMed/MEDLINE, Embase, and Scopus through October 3, 2026.
Abstract
The duration of reduced robotic operative exposure associated with deterioration in technical performance, and the minimum recent case frequency needed to preserve performance, remain uncertain. We systematically reviewed PubMed/MEDLINE, Embase, and Scopus through October 3, 2026. Eligible studies assessed robotic operators after proficiency, training, or established practice in relation to exposure gaps or recent case frequency. Study quality was appraised using MERSQI. Technical-quality (T_skill*) and efficiency (T_eff*) vulnerability thresholds were estimated using separate Bayesian interval-censored models. Twenty-four reports representing 22 study clusters were included (median standardized MERSQI, 11.8/18). In the primary analyses, the exploratory cross-study posterior median vulnerability thresholds were 41.6 days for technical quality (95% credible interval [CrI], 9.0-143.5) and 48.9 days for efficiency (95% CrI, 9.4-192.9). Model-implied probabilities of threshold onset by 90 days were 73.2% and 66.4%, respectively. Broad sensitivity analyses incorporating retention-favorable evidence shifted the medians to 110.8 and 89.4 days. A pooled recent-volume threshold was not identifiable; fewer than two versus at least two robotic cases monthly represented only an exploratory boundary. Measurable robotic performance vulnerability may emerge within weeks of reduced exposure, but timing varies substantially and broader retention-inclusive sensitivity analyses yield later estimates. No universal minimum-volume or credentialing cutoff is supported.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association Between Video-Derived Digital Operative Metrics and GEARS Scores in Robotic Surgery and Development of an Exploratory Multivariable Model.Journal of clinical medicine · 2026
- Delayed Retention of Technical Surgical Skills Following Virtual, Augmented, and Mixed-Reality Simulation: A Systematic Review and Meta-analysismedRxiv · 2026
- Surgeons' Perception Questionnaire on Robotics (SPQR): development and preliminary validation of a surgeon-reported instrument for robotic surgery.Journal of robotic surgery · 2026
- SAFER: a simulation-based assessment tool for emergency robotic undocking with multisource validity evidence.Surgical endoscopy · 2026
- Textbook outcome-based performance assessment during transition to the da Vinci SP system in reduced-port robotic gastrectomy.Journal of robotic surgery · 2026
- Testing the "use it or lose it" hypothesis: laparoscopic performance after robotic adoption in bariatric surgery.Surgery for obesity and related diseases : official journal of the American Society for Bariatric Surgery · 2026