Surgical Intelligence Labs: a technical feasibility study of smartphone-based egocentric data capture and computational retargeting for robotic surgery.
Mustafa Khan, João Bombardelli
Division of Plastic Surgery, UTHealth Houston, Houston, TX, USA. mustafa.t.khan@uth.tmc.edu. · Division of Plastic Surgery, UTHealth Houston, Houston, TX, USA.
Key points
From the paper's conclusion- We developed and evaluated a smartphone-based method for capturing first-person video, head pose, device motion and hand motion in a non-clinical simulation.
Abstract
Surgical robotics could benefit from demonstrations of manual operating-room work, yet most existing surgical datasets emphasize endoscopic video or robot kinematics. We developed and evaluated a smartphone-based method for capturing first-person video, head pose, device motion and hand motion in a non-clinical simulation. Surgical Intelligence Labs is an iPhone application that records first-person video with synchronized ARKit camera pose and device motion. Apple Vision provides 21 two-dimensional hand keypoints per hand; an articulated model fits these keypoints in three dimensions and maps the fitted motion computationally to humanoid and bimanual robot models. Testing used two author-made, non-clinical recordings, including a 63-s bare-hand suturing simulation. The manuscript distinguishes implemented local capture functions from planned operating-room collection and de-identification workflows. In the 63-s suturing simulation, ARKit reported normal tracking for all 1,877 video frames and the phone pointed a mean 55° below the horizon. Both hands were detected in 97% of sampled frames and 99% of tracked hand observations retained a three-dimensional fit. These frame-level proportions describe a single temporally correlated sequence, not independent trials. Position-based retargeting reproduced median thumb-to-fingertip gaps within 2 mm of the fitted human-hand gaps; because gap matching is included in the position-based retargeting objective, this is a fitted-model geometric consistency check rather than independent validation. Numerical inverse kinematics solved all 300 G1 + and 200 WidowX deliberately reachable test targets (median position errors 1.1 and 0.35 mm, respectively). A consumer smartphone can capture synchronized first-person video, head pose, device motion and hand landmarks and map fitted hand motion to robot models computationally. This single-operator, non-clinical study establishes technical feasibility of the capture and processing pipeline; it does not establish absolute hand accuracy, generalizable performance, physical robot execution, policy learning or clinical readiness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EgoSurgHands: An Egocentric 3D Hand Pose Dataset & Benchmark for Open Surgery TrainingarXiv · 2026
- Scalable, Intuitive, Mixed Reality-Based Semi-Autonomous Robotic Telemanipulation for the Execution of a Fine-Grained Bimanual TaskarXiv · 2026
- Physics-Based Simulation of a Heterogeneous Over-Constrained Robot for Vitreoretinal Surgery Training.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2026
- SurgTAP-3D: A Large-Scale Cross-Surgery Video Dataset with Contact-Aware 3D Motion TrackingarXiv · 2026
- A Granular Interaction Framework for Surgical Robotic Digital Twins: Enabling Realistic Segment-Level Manipulation in Extended RealityInternational Journal of Computer Assisted Radiology and Surgery · 2026
- Human Demonstrations as Post-Training Data for Any Robot Body: Retargeting the Object, Not the HandarXiv · 2026