Journal of robotic surgery

Robotic and open repair of complex ventral and incisional hernias with the Tissue Approximating System (TAS): a pilot feasibility study.

Michael A J Sawyer, Nicolas Zucchini, Michail Koutentakis, Christian A Macias, Abhirami Babu, Charles Egas, Alejandro González Ojeda, Luis Osvaldo Suárez Carreón,

University of Oklahoma School of Medicine, Oklahoma City, OK, USA. · Department of Surgery, Nacogdoches Medical Center, Nacogdoches, TX, 75962, USA. nicolas.zucchini@aob.it.

Observational · n=50

Key points

From the paper's conclusion
  • Overall 30-day complication rates were not significantly different (40.0% vs.

Abstract

Achieving durable primary fascial closure (PFC) in complex ventral and incisional hernias (VIH) without generating excessive midline tension remains a formidable surgical challenge. This pilot study evaluates the feasibility and short-term safety of a novel mechanical fascial traction device, the Tissue Approximating System (TAS), with a historical cohort included to provide clinical context rather than a direct efficacy comparison. A retrospective, observational study evaluated 30 adult patients undergoing complex VIH repair utilizing the TAS with robotic and open approaches. A historical cohort of 50 patients undergoing standard PFC was included strictly to provide contextual baseline data on standard hernia repair morbidity rather than a matched efficacy comparator. Primary endpoints were 30-day postoperative morbidity, stratified by the Clavien-Dindo (CD) classification, and operative metrics, including total operative time (OT) and lysis of adhesions (LOA) time. Statistical analyses utilized independent t-tests, Mann-Whitney U, and Chi-square tests. Despite comparable demographics, the TAS cohort presented with significantly higher baseline anatomical complexity, including larger mean fascial defects (126.7 vs. 50.7 cm², p < 0.001), greater loss of domain (40.0% vs. 4.0%, p < 0.001), and higher rates of recurrent hernias (76.7% vs. 54.0%, p = 0.043). Total OT and LOA times were significantly longer in the TAS group (p < 0.001). Overall 30-day complication rates were not significantly different (40.0% vs. 30.0%, p = 0.301). The TAS cohort had a 0% incidence of life-threatening systemic complications (CD IV-V), with complications predominantly consisting of local wound events. Postoperative pain at two weeks was significantly lower in the investigational group (p = 0.006). At short-term follow-up, no clinical recurrences have been identified in the TAS group. The TAS device was a feasible mechanical adjunct that facilitated 100% PFC in this small cohort of complex hernia defects. These preliminary findings support further evaluation of TAS-assisted closure, including device-related safety, comparative effectiveness, and longer-term durability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Robotic and open repair of complex ventral and incisional hernias with the Tissue Approximating System (TAS): a pilot feasibility study — Science Skim