Robotic-assisted conversion of unicompartmental to total knee arthroplasty: a systematic review.
Carmelo Burgio, Steven G Persaud, Francesco Bosco, Shrey Vachhani, Karlos E Zepeda, David J Mayman, Jonathan M Vigdorchik, Eytan M Debbi
Adult Reconstruction & Joint Replacement Department, Hospital for Special Surgery, New York, USA. burgioc@hss.edu. · Adult Reconstruction & Joint Replacement Department, Hospital for Special Surgery, New York, USA.
Key points
From the paper's conclusion- Conversion of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) presents technical challenges due to bone loss and altered anatomy, often requiring stems or augments.
Abstract
Conversion of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) presents technical challenges due to bone loss and altered anatomy, often requiring stems or augments. Robotic-assisted systems have emerged as a potential solution by improving precision and bone preservation. This systematic review evaluates robotic assistance in UKA-to-TKA conversion and its impact on surgical performance and outcomes. This review followed PRISMA guidelines and was registered in PROSPERO (CRD42025643211). A systematic search of PubMed, Embase, and Scopus was conducted through October 2025. Eligible studies reported outcomes of robotic-assisted UKA-to-TKA conversions with a mean follow-up of 20.9 months. Two reviewers independently screened studies and extracted data on demographics, perioperative variables, functional outcomes, complications, and implant survivorship. Risk of bias was assessed using the ROBINS-I tool. Five studies including 136 patients (140 knees) were analyzed. Most cases (n = 105) used the MAKO SmartRobotics™ System, while the remainder (n = 35) used the ROSA Knee System. No intraoperative conversions to manual technique occurred. Augments were required in 13.6% of cases and stems in 3.6%. Range of motion improved to 119-130° flexion with full extension. Patient-reported outcomes demonstrated improvements in r-WOMAC and OKS, with favorable postoperative FJS. Complication rates ranged from 0 to 11%, including one intraoperative tibial fracture (0.7%), two periprosthetic joint infections, three stiffness cases, and one aseptic loosening. Implant survivorship ranged from 93.2% to 100% at up to 3.6 years follow-up. Robotic-assisted UKA-to-TKA conversion demonstrates reproducible intraoperative performance, minimal need for augments, and favorable short-term outcomes. Longer-term studies are needed to confirm durability.Level of evidence: Level IV.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robotic-assisted unicompartmental knee arthroplasty improves implant positioning without reducing short-term complications : An overview of systematic reviews and a revised meta-analysis.Orthopadie (Heidelberg, Germany) · 2026
- Revision of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty Using the CORITM Imageless System: A Step-By-Step Surgical Technique.SICOT-J · 2026
- Robotic Assisted Versus Manual Unicompartmental Knee Arthroplasty: A Systematic Review and Meta-Analysis.Orthopaedic surgery · 2026
- Robotic-assisted total knee arthroplasty with MAKO is associated with improved functional outcomesBone & Joint Open · 2025
- Cementless versus cemented fixation in robotic-assisted total knee arthroplasty: a systematic review and meta-analysis.Journal of robotic surgery · 2026
- Biomechanical Insights into Robotic-Assisted UKA vs. Conventional UKA: Trends in Fracture Resistance and PatternsBiomechanics · 2026