Automated CT-based quantification of knee osteophytes for robotic-assisted total knee arthroplasty: a multi-cohort study.
Zhiqian Zheng, Do Weon Lee, Sewon Jeon, Hong Yeol Yang, Jong Keun Seon, Ho-Jung Jung, Joong Il Kim, Byung Sun Choi,
Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, Republic of Korea. · Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Republic of Korea.
Key points
From the paper's conclusion- We developed automated CT-based osteophyte quantification and evaluated it against blinded de novo expert-consensus annotations and an intraoperative accessible resected osteophyte volume reference.
Abstract
Preoperative computed tomography (CT) is routinely acquired for planning robotic-assisted total knee arthroplasty (TKA), yet osteophyte burden is not quantitatively characterized. We developed automated CT-based osteophyte quantification and evaluated it against blinded de novo expert-consensus annotations and an intraoperative accessible resected osteophyte volume reference. A human-in-the-loop 3-dimensional U-Net was developed using 387 knee CT scans. The frozen model was evaluated against blinded de novo expert-consensus annotations in two independent external cohorts (100 knees each). Spatial and volume agreement were assessed using Dice coefficient, surface Dice at 1-mm tolerance, 95th-percentile Hausdorff distance (HD95), intraclass correlation coefficient (ICC), mean absolute error, and Bland-Altman analysis. In a prospective cohort of 66 robotic-assisted TKAs, CT-derived total osteophyte volume was compared with the water-displacement volume of accessible osteophytes that were resected and recovered intraoperatively (accessible resected osteophyte volume reference). In the external cohorts, median total Dice was 0.913 and 0.909, surface Dice was 0.944 and 0.945, HD95 was 1.16 and 1.09 mm, and volume ICC was 0.977 and 0.972, respectively. Automated estimates showed conservative volume bias relative to expert consensus (- 0.499 and - 0.365 cc). In the surgical cohort, automated CT-derived volume showed cohort-level agreement with the accessible resected osteophyte volume reference (ICC, 0.876; mean absolute error, 1.224 cc; mean difference, + 0.401 cc; 95% limits of agreement, - 2.785 to + 3.586 cc). Automated CT-based osteophyte quantification showed consistent spatial and volumetric agreement with blinded de novo expert-consensus annotations across two external cohorts and cohort-level agreement with the accessible resected osteophyte volume reference. This scalable method provides a preoperative measure of osteophyte burden for arthroplasty research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Medial expected gap (mEG): a quantitative, biology-guided predictor of coronal plane correction and knee balance in robotic functionally aligned total knee arthroplasty.Journal of robotic surgery · 2026
- 3D QUANTITATIVE MEASUREMENTS OF JOINT SPACING BASED ON SEMI-AUTOMATIC AND AUTOMATIC SEGMENTATION, CONDUCTED 36 MONTHS APART, USING COMPUTED TOMOGRAPHY IMAGES.Osteoarthritis imaging · 2026
- Longitudinal 3D quantification of joint space from CT images: Semi-automatic segmentation and feasibility of nnU-Net automation.Osteoarthritis imaging · 2026
- Comparison of Functional Outcomes and Implant Positioning between a CT-based, Semi-active Robotic System and a CT-free Passive Robotic System in Total Knee Arthroplasty.The journal of knee surgery · 2026
- nnU-NET BASED 3D SEGMENTATION OF HIGH-RESOLUTION KNEE CT SCANS FOR THE ANALYSIS OF SHAPE AND INTRA-ARTICULAR CALCIFICIATIONS.Osteoarthritis imaging · 2026
- A novel method of determining bone mineral density of the knee from a pre-surgical CT scan to aid in surgical planning.Osteoarthritis imaging · 2026