Development and validation of objective performance metrics for robot-assisted basic surgical skills in a simulated anastomosis task using a single-port robotic system.
Edoardo Beatrici, Valerio Santarelli, Alessio Guidotti, Francesco Pepillo, Mario de Angelis, Attilio Barretta, Francesco Cei, Nicola Frego,
ORSI Academy, Melle, Belgium. · ORSI Academy, Melle, Belgium. va.santarelli@uniroma1.it.
Key points
From the paper's conclusion- The proposed metrics showed robust construct validity and reliability, and support PBP training and assessment for the SP platform. The proposed benchmark, as well as its clinical impact, requires confirmation and prospective evaluation.
Abstract
INTRODUCTION: The chicken anastomosis task is a widely adopted model for training robotic suturing and knot-tying. Aim of this study was to develop and validate objective performance metrics for this task on the Single-Port (SP) robotic platform and to establish a proficiency benchmark for training and assessment. METHODS: Seven experts in robotic surgery training and Proficiency Based Progression (PBP) developed the metrics for the SP chicken anastomosis task. The proposed metrics were refined among a panel of n = 14 participants with significant experience in PBP and/or robotics and/or the SP system, through a modified Delphi process. Construct validity was assessed by comparing recorded performances of n = 12 expert ( ≥100 SP RARPs) and n = 12 novice surgeons, blindly scored by two reviewers. Proficiency benchmarks were established based on performance distribution. RESULTS: Delphi consensus achieved 100% agreement on the proposed performance metrics (n = 5 steps, n = 20 errors, n = 1 failure to progress and n = 4 critical errors [CE]). Novices were twice more likely to commit a CE (n = 6 vs. n = 3). Among participants who completed the task without CEs, novices required significantly longer completion times (mean 25.3 min, 95%CI 18.0-32.7 vs. 11.2 min, 95%CI 8.5-13.9; p = 0.003) and committed a significantly higher mean number of errors (12.3, 95%CI 8.6-16.1 vs. 8.1, 95%CI 6.6-9.6, p = 0.033). Calculated Inter-Rater Reliability (IRR: agreements/agreements+disagreements) was 0.96. Proficiency benchmarks were defined as: absence of CEs and < 10 errors. CONCLUSIONS: The proposed metrics showed robust construct validity and reliability, and support PBP training and assessment for the SP platform. The proposed benchmark, as well as its clinical impact, requires confirmation and prospective evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Objective assessment of robot-assisted suturing using a weighted performance score and a virtual simulation platform.Journal of robotic surgery · 2026
- ROBECS one: feasibility study of a structured robotic curriculum and a proficiency-based framework.Journal of robotic surgery · 2026
- Development and validation of an objective skills scoring system for robotic inguinal hernia repairsnpj Digital Medicine · 2026
- Robotic Simulation Training in Reducing the Learning Gap Between Expert Surgeons and Novice Trainees: A Prospective Single-Blinded Study.Journal of surgical education · 2026
- Expert-based classification on the technical difficulty of single-port urological robotic procedures.Journal of robotic surgery · 2026
- A Task-Specific Performance Rating Scale for Laparoscopic Intracorporeal Suturing and Knot Tying: Development and Initial Evaluation.Journal of laparoendoscopic & advanced surgical techniques. Part A · 2026