Clinical performance of da Vinci 5 versus Xi for robotic anatomic lung resection: a propensity-weighted analysis.
Nikolaos Pachos, Costas Bizekis, Amie J Kent, Ioannis Karikis, Stephanie H Chang, Michael Zervos, Robert J Cerfolio
Department of Cardiothoracic Surgery, Division of Thoracic Surgery, NYU Langone Health, New York, NY, USA. nikolaos.pachos@nyulangone.org. · Department of Cardiothoracic Surgery, Division of Thoracic Surgery, NYU Langone Health, New York, NY, USA.
Key points
From the paper's conclusion- We compare perioperative safety, operative efficiency and early oncologic quality between DV5 and Xi robotic platforms for anatomic lung resection.
Abstract
The da Vinci 5 (DV5) system has purported advantages over existing platforms, including forced feedback. We compare perioperative safety, operative efficiency and early oncologic quality between DV5 and Xi robotic platforms for anatomic lung resection. A total of 419 robotic lung resections were performed between January 2025 and August 2026. Propensity-score overlap weighting balanced and matched 294 patients (47 DV5, 247 Xi) for age, sex, ASA class, BMI, forced expiratory volume in 1 s, tumor size, clinical T and N category, resection type and laterality. Effects were reported with robust and bootstrap 95% confidence intervals. Sensitivity analyses included 1:1 and 1:3 propensity matching comparisons and E-value assessment. From January 2025 to August 2026, 294 patients (47 DV5, 247 Xi) had balanced baseline characteristics (SMD < 0.01). Operative time was shorter with DV5 (96.4 vs. 118.7 min; 95% CI, - 36.2 to - 8.5). Lymph node yield was comparable (DV5 29.9 vs. Xi 31.6; [- 7.2 to + 3.7]). Blood loss (p < 0.01), length of stay (1.05 vs. 1.28 days; [- 0.53, + 0.06]) and stapler loads (8.5 vs. 9.6; [- 2.81 to + 0.55]) were numerically lower with DV5. Major complications were numerically lower with DV5 (1/47 [2.0%] vs. 20/247 [8.2%]; -16.0 to + 3.6). Both had 100% R0 resections and no conversion. There was no 30- or 90-day mortality. In this first clinical comparison of da Vinci 5 and Xi for robotic anatomic lung resection, DV5 preserved the safety and oncologic quality of Xi while being associated with shorter operative times. Prospective multi-institutional studies are required to confirm these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Operative efficiency and short-term outcomes of da Vinci 5 versus da Vinci Xi in robotic rectal cancer surgery: an overlap-weighted cohort study with an exploratory case insights analysis.Journal of robotic surgery · 2026
- Comparative functional and oncologic outcomes of radical prostatectomy using the da Vinci Xi versus da Vinci 5: an inverse probability-weighted analysis.World journal of urology · 2026
- Comparative perioperative and oncological outcomes of the da Vinci Xi versus Si robotic surgical systems in rectal cancer surgery: a systematic review and meta-analysis.Journal of robotic surgery · 2026
- Initial surgical results of subcostal uniportal robotic lung resection: a study of the perioperative outcomes and a CUSUM analysis of the learning curve.Surgery today · 2026
- Force feedback and vocal cord dysfunction after robotic esophagectomy: a comparison of the da Vinci 5 and Xi systems.Journal of robotic surgery · 2026
- Prospective Comparison of Two Robotic Platforms for the Performance of Radical Prostatectomy: Versius vs. DaVinci.Cancers · 2026