AI-based smoke removal in robotic urooncologic surgery: a clinical pilot study.
Leonhard Buck, Silja Janßen, Jakob Kohler, Julian Risch, Anton Moderegger, Daniar Osmonov, Jonas Jarczyk, Axel Merseburger,
Department of Urology, University Hospital Schleswig-Holstein, 24105, Kiel, Germany, Campus Kiel. leonhard.buck@uksh.de. · Department of Computer Science, Christian-Albrechts-University of Kiel, 24118, Kiel, Germany.
Key points
From the paper's conclusion- Overall utility was rated positively by 40%, neutrally by 35% and negatively by 25%.
Abstract
Surgical smoke from electrocautery limits visibility during robot-assisted oncological surgery by obscuring tumor margins, blood vessels and anatomical landmarks. AI-based smoke removal demonstrated promising technical performance, structured clinical evaluation remains limited. This pilot study examined surgeons' perceptions of a temporally consistent 3D U-Net applied to intraoperative smoke. Twenty urologists and residents retrospectively assessed ten pairs of endoscopic videos offline, showing original and AI-processed clips. A questionnaire evaluated general impressions (seven items, five-point Likert scale), direct comparisons across four image dimensions, open-ended feedback and overall utility. Visibility of anatomical details and depth perception were rated equal to the smoke-affected original by 75% of participants and slightly better by 25%. Color fidelity was rated equal by 85% and slightly better by 15%. None rated these dimensions worse (0/20, exact 95% CI 0 to 16.8%), and no participant selected the highest rating. Image stability was rated worse by 20%. Half disagreed that the processed footage appeared clearer. Overall utility was rated positively by 40%, neutrally by 35% and negatively by 25%. In this small, unblinded, single-institution retrospective pilot study, AI processing was not associated with a perceived worsening of anatomical detail, depth perception or color fidelity. However, confidence intervals remain wide and the study was not designed to establish equivalence. Most participants perceived no improvement in image clarity or orientation support. Artifact reduction, real-time performance and blinded multicenter evaluation are required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-powered semantic segmentation model for enhanced ureteral mapping and real-time instrument feedback in robotic colorectal surgery.Journal of robotic surgery · 2026
- Toward the intelligent operating room: Artificial intelligence and computer vision applications in surgery.Turkish journal of surgery · 2026
- Artificial Intelligence‐Based Recognition of the Prostatic Capsule During Nerve‐Sparing Robot‐Assisted Radical ProstatectomyInternational Journal of Urology · 2026
- Artificial Intelligence–Based Analysis of Laparoscopic Imaging for Intraoperative Surgical Decision SupportAnnual Review of Biomedical Engineering · 2026
- Surgical RARP copilot: a vision language model for robot-assisted radical prostatectomynpj Digital Surgery · 2026
- The OR black box in urology: A survey on patient acceptance and confidence in AI-assisted surgery.BJUI compass · 2026