Hospital costs and procedural learning curves of robotic mitral valve surgery: a systematic review and meta-analysis.
Dang Nguyen, Minh H N Le, Amira Mohamed Taha, Heath Rutledge-Jukes, Phan Quang Thuan, Tam Tran, Pham Thao Vy Le, Trang Thi Bich Le,
Harvard T.H. Chan School of Public Health, Harvard University, Boston, MA, USA. · Section of Cardiovascular Medicine, Department of Internal Medicine, Yale School of Medicine, New Haven, CT, USA.
Key points
From the paper's conclusion- This study aimed to synthesize existing evidence comparing robotic and conventional mitral valve procedures regarding overall hospital expenses, intraoperative and post-procedure costs, as well as learning trajectory parameters including aortic cross-clamp and cardiopulmonary bypass durations.
Abstract
Robotic-assisted mitral valve surgery offers a less invasive alternative to traditional open sternotomy, with potential benefits including faster recovery and reduced morbidity. However, the higher upfront expenses have slowed its broader acceptance. This study aimed to synthesize existing evidence comparing robotic and conventional mitral valve procedures regarding overall hospital expenses, intraoperative and post-procedure costs, as well as learning trajectory parameters including aortic cross-clamp and cardiopulmonary bypass durations. A systematic search of PubMed, Scopus, Web of Science, and the Cochrane Library was conducted up to May 2026 to identify studies reporting cost or learning curve outcomes. A random-effects model with restricted maximum likelihood estimation was used in R software for all pooled analyses. Seventeen studies met inclusion criteria. Total hospital costs from five studies (91,541 participants) showed no significant difference between approaches (MD + 1,620 USD; p = 0.423) with high heterogeneity (I² = 99.3%). Leave-one-out analysis excluding one large US database study demonstrated significantly lower total costs for robotic surgery (p < 0.001) with no heterogeneity. Robotic procedures had higher intraoperative costs (MD + 2,144 USD; p < 0.001) but lower postoperative costs (MD -556 USD; p < 0.001). The learning phase trended toward longer cross-clamp and bypass times versus proficiency, with no differences between proficiency and mastery phases. Robotic mitral surgery demonstrated no significant difference in total hospital costs compared with conventional approaches in the primary analysis, with higher intraoperative costs offset by lower postoperative expenses. However, substantial heterogeneity and limited learning curve evidence prevent definitive conclusions. Future studies should adopt standardized economic and learning curve methodologies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Health economic and hospital resource use in isolated mitral valve repair in more than 8000 patients: Robotic versus nonrobotic approaches.JTCVS open · 2026
- Robotic mitral valve surgery in 2026: outcomes, adoption, the learning curve, and real-world evidence.Current opinion in cardiology · 2026
- Prior minimally invasive experience and the robotic mitral valve learning curve: a focused narrative review and the tactile-visual decoupling hypothesis.Journal of robotic surgery · 2026
- Advantages and Limitations of the Use of Robots in Minimally Invasive Mitral Valve Repair: Results From a Matched Direct Comparison.Innovations (Philadelphia, Pa.) · 2026
- Outcomes following the first 100 cases of a new robotic mitral valve program.JTCVS open · 2026
- Mitral Valve Repair in Patients With Class I Obesity: A Propensity-Matched Analysis.JACC. Advances · 2026