Immersive head-mounted control of a robotic laparoscopic camera: a usability and accuracy evaluation.
Sérgio G Pereira, Pedro Morais, Fernando Rocha, Nuno S Osório, Estela Vilhena, Estevão Lima, João L Vilaça
2Ai - Applied Artificial Intelligence Laboratory, School of Technology, Polytechnic University of Cávado and Ave, Barcelos, Portugal. sfpereira@ipca.pt. · 2Ai - Applied Artificial Intelligence Laboratory, School of Technology, Polytechnic University of Cávado and Ave, Barcelos, Portugal.
Key points
From the paper's conclusion- In conclusion, this study demonstrates that VR control for laparoscopic cameras can be compared to existing joysticks in terms of usability, but its control method requires further refinement to reduce task completion time.
Abstract
Robotic surgery has addressed limitations of minimally invasive surgery, namely: assistant hand tremors during camera holding and communication errors among team members. However, advanced systems require substantial investment and operating-room space. As a result, recent studies have explored laparoscopic camera control through virtual and augmented reality (VR/AR) devices, though their usability and accuracy relative to existing solutions remain unclear. This study presents a novel immersive framework using an Oculus Quest 3 headset to control a KUKA LBR iiwa robot, comparing its accuracy and time-response (TR). Moreover, its usability was compared against two state-of-art controllers: Image1Pilot and SoloAssist Joystick. TR was measured by moving the VR headset with one robot while a second robot reproduced the transmitted motion. Tracking accuracy was assessed via a four-point trajectory, using simultaneously measurements from the VR, robot flange, and an optical tracking system. Usability and task performance were assessed in 35 participants using a camera-control task and the System Usability Scale (SUS). Results showed an average TR of 143.10 ± 28.50ms, and a maximum positional error of 12.60 mm over a 150 mm displacement. SUS scores revealed no statistically significant differences in usability across interfaces (H = 0.174, p = 0.917). All achieved an "Acceptable" rating (SUS ≈ 70). In the 3rd trial, The Image1Pilot enabled significantly faster task completion than the VR interface , though no significant difference versus the SoloAssist Joystick. In conclusion, this study demonstrates that VR control for laparoscopic cameras can be compared to existing joysticks in terms of usability, but its control method requires further refinement to reduce task completion time.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantifying laparoscopic camera workspace and kinematics during robot-assisted radical prostatectomy.Journal of robotic surgery · 2026
- A VR Training System for Robot-Assisted Vascular Intervention with Dual-Mode Control and Model-Based Interaction ResponsearXiv · 2026
- ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive SurgeryarXiv · 2026
- A Real-World Grounded Usability Evaluation of VR Interaction Techniques Across Discrete, Spatial, and Continuous Tasks.Sensors (Basel, Switzerland) · 2026
- Surgeon-authorized natural-language and instrument-tracking shared control for robotic laparoscope holding: the EndoVISTA simulator and porcine feasibility study.Journal of robotic surgery · 2026
- A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input DevicearXiv · 2026