Single-port robotic areolar thyroidectomy: technical feasibility and clinical outcomes of 64 consecutive cases.
Myunghan Yu, Dongsik Bae, Jaewan Jeon, Gicheon Lee, Soohyeon Lee, Dohoon Koo
Department of Surgery, Haeundae Paik Hospital, Inje University College of Medicine, 875 Haeundae-ro, Haeundae-gu, 48108, Busan, Republic of Korea. · Department of Radiation Oncology, Haeundae Paik Hospital, Inje University College of Medicine, Busan, Republic of Korea.
Key points
From the paper's conclusion- These findings support SPRA as a safe and feasible integrated platform for remote-access thyroidectomy.
Abstract
Single-port robotic areolar (SPRA) thyroidectomy is a recent refinement of the bilateral axillo-breast approach (BABA) that employs the da Vinci single-port system to establish a single-trajectory corridor while preserving a scarless neck. However, clinical data remain limited. The present study evaluated whether SPRA is clinically feasible and technically safe. This retrospective study analyzed 64 consecutive women who underwent SPRA at a single center between March and September 2025. We compared flap dissection extent between SPRA and BABA using a standardized grid-based model and analyzed perioperative outcomes. Console time was analyzed by laterality, body mass index (BMI), and learning phase via cumulative sum (CUSUM) analysis. Less-than-total and total thyroidectomy were performed in 59 (92.2%) and 5 (7.8%) patients, respectively. The mean console time was 69.3 ± 27.4 min and did not differ significantly by laterality or correlate with BMI. CUSUM analysis showed an inflection point at case 15; the late phase (cases 16-60) had significantly shorter console times than the early phase (cases 1-15) (62.9 vs. 82.4 min; median difference, 17.0 min; p = 0.017). Modeled flap dissection area was approximately 28% smaller for SPRA than for BABA. No conversions occurred. Transient vocal cord palsy affected six patients (9.4%) and transient hypoparathyroidism affected one (20% of total thyroidectomies), with no permanent complications. SPRA demonstrated a smaller estimated flap dissection, consistent operative performance, and early stabilization of console time. These findings support SPRA as a safe and feasible integrated platform for remote-access thyroidectomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single-port, via a midline approach, Robotic Transaxillary Thyroidectomy (SMART-Thyroidectomy): description of the technique and evaluation of feasibility in the first case series.Journal of robotic surgery · 2026
- Recent advances in single-port robotic thyroidectomy: evolution, techniques, and clinical outcomesAnnals of Surgical Treatment and Research · 2026
- From technical feasibility to patient-centered selection in remote-access thyroidectomy: the AGES framework in the single-port robotic era.Frontiers in endocrinology · 2026
- Mastering Single Port Robot-Assisted Partial Nephrectomy with the Low Anterior Access: A Learning Curve Analysis with Comparison of Perioperative OutcomesJournal of Endourology · 2025
- Feasibility of Transoral Robotic Total Laryngectomy With the Da Vinci Single Port Robotic System.Laryngoscope investigative otolaryngology · 2026
- Single-port versus multiport robotic assisted peritoneal flap vaginoplasty: perioperative, surgical and analgesic outcomes from a single-center cohort.Journal of robotic surgery · 2026