Feasibility of a novel multi-device robotic system for multiple neurointerventional procedures: pre-clinical validation in porcine models.
Yongxin Zhang, Hongyu Ma, Jiayan Li, Fei Guo, Jian Guo, Jun Sun, Jianmin Liu, Shuxiang Guo,
Department of Neurovascular Center, Changhai Hospital, Shanghai, 200433, China. · Shenzhen Nanshan District Peoples Hospital, Shenzhen, 518052, China.
Key points
From the paper's conclusion- Therefore, we developed a novel robotic system, which was capable of simultaneous coaxial control of three catheters and one guidewire, coupled with rapid-exchange functionality.
Abstract
While the application of a robotic system in neurointerventional procedures has gained notable attention, the current robotic assistance is unsatisfactory. Therefore, we developed a novel robotic system, which was capable of simultaneous coaxial control of three catheters and one guidewire, coupled with rapid-exchange functionality. To evaluate the feasibility of the multi-device robotic system for diagnostic angiography, carotid artery stenting (CAS), vertebral artery (VA) stenting, flow diverter (FD) deployment and aneurysm coiling through preclinical study. The robotic system was tested for feasibility to complete all procedural steps of 5 neurovascular interventions navigating or deploying a variety of common neurovascular devices including the guidewires, catheters, micro-guidewires, microcatheters, coils, the FD, the cerebral protection device and different types of stents. The experimental lateral wall aneurysms were created in 3 live and anesthetized pigs by end-to-side anastomosis using an autologous venous pouch. A total of five surgically created aneurysms were allocated to coiling (n = 2), FD implantation (n = 2) and coiling + FD (n = 1). One VA and one CA were utilized for stenting. All planned procedures were performed successfully with no relevant technical complications or vascular damage. Notably, almost all procedural steps, from different navigation of catheters to device deployment, were completed robotically, with manual intervention limited to radiation-free device exchanges and loading. Robot-assisted operation does not increase the complexity of procedures. This pilot study demonstrates that the multi-device robotic system is feasible for cerebral angiography, navigation of the guiding catheter, aneurysm coiling, FD deployment, VA stenting and CAS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Portable endovascular disposable robotic assistant (PEDRA) for image-guided peripheral endovascular interventions: technical feasibility, safety, and future implications.CVIR endovascular · 2026
- Endovascular robotic-assisted system for cerebral angiography (ERASE): Rationale, design, and protocol of a multicenter randomized controlled trial.Neurosurgical review · 2026
- Robot-assisted versus manual neuroendovascular interventions - updated systematic review and pairwise meta-analysis.AJNR. American journal of neuroradiology · 2026
- A Novel Hybrid Gripper for Endovascular Interventions Using Collaborative Robotic ArmsThe International Journal of Medical Robotics and Computer Assisted Surgery · 2026
- Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.Journal of robotic surgery · 2026
- Multistage Preclinical Evaluation of MRI-Guided Stenting for Coarctation of the Aorta using in vitro and Porcine Models.Cardiovascular and interventional radiology · 2026