Robotic-Assisted Versus Laparoscopic Revisional Roux-en-Y Gastric Bypass: A Systematic Review and Meta-Analysis.
Felippe Furlan Kelher, Vitória Maia Corrêa, Fernanda de Moraes Nava, Lucas Monteiro Delgado, Cláudia Theis, Sérgio Mazzola Poli de Figueiredo, Fábio Israel Lima Castelo Branco Marques, Bernardo Fontel Pompeu
Department of Surgery, Hospital Heliópolis, São Paulo, Brazil. · Department of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil. ldelgado@ufmg.br.
Key points
From the paper's conclusion- Robotic-assisted revisional or conversional RYGB was associated with lower odds of overall morbidity and of intervention for bleeding, with no significant differences in the remaining outcomes, including comparable operative time. Both findings were borderline and sensitive to study composition, and the very low certainty of evidence precludes conclusions of superiority.
Abstract
BACKGROUND: Robotic-assisted surgery has been increasingly adopted for complex revisional bariatric procedures, but whether it provides clinical advantages over conventional laparoscopy for revisional Roux-en-Y gastric bypass (RYGB) remains uncertain. This systematic review and meta-analysis aimed to provide an updated, procedure-specific synthesis of comparative evidence evaluating robotic-assisted versus laparoscopic revisional or conversional RYGB. METHODS: We searched PubMed/MEDLINE, Scopus, and CENTRAL from inception through August 2026 for comparative studies of adults undergoing robotic-assisted versus laparoscopic revisional or conversion RYGB. Random-effects meta-analyses were performed using odds ratios (ORs) for dichotomous outcomes and mean differences (MDs) for continuous outcomes, with 95% confidence intervals (CIs). Risk of bias and certainty of evidence were assessed using ROBINS-I and GRADE, respectively. RESULTS: Five retrospective comparative studies comprising 27,341 patients were included. Robotic-assisted surgery was associated with lower odds of overall morbidity (OR 0.65, 95% CI 0.43-1.00; p = 0.049; I2 = 20.9%). No statistically significant differences were observed in reoperation (OR 0.61, 95% CI 0.22-1.68), leak (OR 0.48, 95% CI 0.11-2.00), hemorrhage/bleeding (OR 0.73, 95% CI 0.31-1.72), mortality (OR 0.62, 95% CI 0.04-8.73), length of stay (MD - 0.71 days, 95% CI - 1.66 to 0.24), or operative time (MD 13.43 min, 95% CI - 28.24 to 55.11). Robotic surgery was also associated with lower odds of intervention for bleeding (OR 0.55, 95% CI 0.34-0.88; I2 = 0%). Both significant results were sensitive to study composition in leave-one-out analyses. Certainty of evidence was very low for all outcomes. CONCLUSIONS: Robotic-assisted revisional or conversional RYGB was associated with lower odds of overall morbidity and of intervention for bleeding, with no significant differences in the remaining outcomes, including comparable operative time. Both findings were borderline and sensitive to study composition, and the very low certainty of evidence precludes conclusions of superiority.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Procedure-specific outcomes of robotic versus laparoscopic Roux-en-Y gastric bypass and biliopancreatic diversion with duodenal switch across a decade of MBSAQIP adoption.Journal of robotic surgery · 2026
- Safety and Efficiency of Robotic Versus Laparoscopic Revisional Bariatric Surgery: A Systematic Review and Meta-Analysis.Medical sciences (Basel, Switzerland) · 2026
- Latest Outcomes in Robotic-Assisted Bariatric Surgery: Contemporary Analysis of Laparoscopic Versus Robotic Sleeve Gastrectomy and Roux-en-Y Gastric Bypass.Surgical laparoscopy, endoscopy & percutaneous techniques · 2026
- Robotic Bariatric Surgery: A Critical Review of Clinical Outcomes, Learning Curves, and Economic Considerations.Digestive surgery · 2026
- Perioperative morbidity and surgical outcomes of robot-assisted versus open radical cystectomy in obese patients (BMI ≥ 30 kg/m²): a systematic review and meta-analysis.Journal of robotic surgery · 2026
- Real Robotic 3-arm, 3-port versus laparoscopic Roux-en-Y gastric bypass: a prospective single-center comparative study of operative time, costs and short-term outcomes.Journal of robotic surgery · 2026