Obesity surgery

From Visual Estimation to Computer Vision-Based Intraoperative Distance Measurement for Biliopancreatic Limb Assessment: A Pilot Study.

Shahab Shahabi Shahmiri, Seyed Mohammad Mahdi Khadem, Aman Abdulmawjood Taha, Sherko Abbas Nadir, Haval Sabir Faqismail, Delaram Moosavi, Amirhossein Davarpanah Jazi, Mohammad Kermansaravi

Department of Surgery, Division of Minimally Invasive and Bariatric Surgery, Center of Excellence of European Branch of International Federation for Surgery of Obesity, Rasool-e Akram Hospital, Iran University of Medical Sciences, Tehran, Iran. · Department of Surgery, Division of Minimally Invasive and Bariatric Surgery, Center of Excellence of European Branch of International Federation for Surgery of Obesity, Rasool-e Akram Hospital, Iran University of Medical Sciences, Tehran, Iran. smmehdikhadem@gmail.com.

Key points

From the paper's conclusion
  • A YOLOv11-based computer vision pose-estimation pipeline demonstrated technical feasibility for calibrated intraoperative distance measurement. Ruler-based validation provided preliminary evidence of measurement accuracy; however, clinical usefulness, including complete BPL measurement and integration into the surgical workflow, requires prospective validation in larger datasets.

Abstract

INTRODUCTION: Biliopancreatic limb (BPL) length is a clinically important technical variable in gastric bypass surgery, yet intraoperative limb measurement is commonly based on visual estimation. This pilot study evaluated the feasibility of a measurement-oriented computer vision (CV) pipeline for calibrated intraoperative BPL-related distance assessment. METHODS: A public laparoscopic tool dataset was adapted for a CV algorithm (YOLOv11) to perform instrument detection and keypoint pose estimation. Two keypoints were used: the distal tip of the grasper and the interface where the tip meets the grasper body. The pipeline detected paired laparoscopic graspers, used a visible 2.5-cm grasper-tip segment for in-scene calibration, and converted inter-instrument pixel distance into centimeters. Model performance was evaluated using tool detection and pose estimation metrics. Surgeon-estimated 5-cm measurements were compared with calculated measurements derived from CV, and external validation was assessed using a sterile ruler reference in the operation field. RESULTS: Seventy-four intraoperative measurement instances and 10 laparoscopic surgical scenes for ruler-based external validation measurements were analyzed using two variants of YOLOv11. YOLOv11-Large achieved slightly higher graspers detection metrics than YOLOv11-Medium (87.58% vs. 86.75%), whereas YOLOv11-Medium achieved higher precision (98.62% vs. 96.01%); which means lower false-positive graspers detections. Pose estimation metrics1 were nearly identical (92.84% vs. 92.85%). The mean length measurements derived from CV was 5.415 cm (95% CI, 5.093-5.737). Bland-Altman analysis reveals a small systematic underestimation by surgeons relative to CV-derived measurements (-0.415 cm, with 95% limits of agreement from - 3.139 to 2.308 cm). The surgeon estimate was within +/-1.0 cm of the measurements value in 56.8% of cases. In ruler validation, the mean deviation from the known 5.00-cm reference was - 0.022 cm (95% CI, -0.336 to 0.292). CONCLUSION: A YOLOv11-based computer vision pose-estimation pipeline demonstrated technical feasibility for calibrated intraoperative distance measurement. Ruler-based validation provided preliminary evidence of measurement accuracy; however, clinical usefulness, including complete BPL measurement and integration into the surgical workflow, requires prospective validation in larger datasets.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers