  • Purpose This prospective study evaluated the 1 year safety and efficacy of stereotactic arrhythmia radioablation (STAR) delivered using the CyberKnife system for refractory ventricular tachycardia (VT) in Japanese patients, in accordance with a prespecified clinical protocol.

Abstract

PURPOSE: This prospective study evaluated the 1 year safety and efficacy of stereotactic arrhythmia radioablation (STAR) delivered using the CyberKnife system for refractory ventricular tachycardia (VT) in Japanese patients, in accordance with a prespecified clinical protocol. MATERIALS AND METHODS: Three male patients with radiofrequency catheter ablation (RFCA)-refractory VT and structural heart disease, namely hypertrophic cardiomyopathy (HCM), dilated cardiomyopathy (DCM), and ischemic cardiomyopathy (ICM), were enrolled. A single fraction of 25 Gy was delivered to the target volume defined by multimodal image fusion. The primary endpoint was the absence of Grade ≥ 3 treatment-related adverse events within 12 months. RESULTS: The primary endpoint was achieved, with no acute or subacute Grade ≥ 3 toxicities observed in any patient during the first year. Although all patients experienced a reduction in VT burden, the clinical course differed by etiology. Cases 2 (DCM) and 3 (ICM) showed typical responses, including delayed efficacy and late recurrence requiring repeat RFCA. In contrast, Case 1 (HCM), with a substantially larger target volume (133 mL), showed a rapid response but a progressive decline in left ventricular ejection fraction by myocardial scintigraphy, from 59.7% to 40.0%, during the 24 month extended follow-up. CONCLUSION: STAR demonstrated preliminary feasibility as a noninvasive salvage therapy for refractory VT in this initial Japanese pilot experience. However, the late functional decline observed in Case 1 highlights the need for long-term follow-up and myocardium-sparing techniques for large target volumes. (jRCTs042230030).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Prospective evaluation of stereotactic arrhythmia radioablation for refractory ventricular tachycardia: initial clinical experience in Japan — Science Skim