Japanese Journal of RadiologyOpen accessMedicine

Correlation of tumor maximum standardized uptake value from 18F-BPA PET and boron neutron capture therapy tumor dose with treatment outcomes in head and neck cancer: a retrospective analysis

Yuki Yoshino, Satoshi Takeno, Teruhito Aihara, Kayako Isohashi, Naonori Hu, Yasukazu Kanai, Akinori Sasaki, Mai Nojiri,

Kyoto Prefectural University · Osaka Medical and Pharmaceutical University

Observational · n=30

Key points

From the paper's conclusion
  • We investigated the correlation of 1 ⁸F-BPA PET SUVmax and individual model doses with treatment response.

Abstract

Abstract Purpose Boron neutron capture therapy (BNCT) dose planning conventionally uses a tumor-to-blood (T/B) ratio derived from the tumor maximum standardized uptake value (SUVmax) of fluorine-18-labeled 4-borono-L-phenylalanine ( 1 ⁸F-BPA) positron emission tomography (PET) (individual model). It remains unclear whether tumor SUVmax or individual model doses predict outcomes in accelerator-based BNCT for head and neck cancer (HNC). We investigated the correlation of 1 ⁸F-BPA PET SUVmax and individual model doses with treatment response. Materials and methods We retrospectively analyzed 30 patients with HNC treated with accelerator-based BNCT (2020–2021). The Kaplan–Meier method was used for survival analysis. Dose parameters (Dmax, Dmin, and D80%) were calculated using the uniform model (T/B = 2.5) and the individual model (T/B = Tumor SUVmax/Blood-pool SUV). Correlations between tumor SUVmax or dose parameters and best treatment response [complete response (CR) vs. non-CR] were evaluated using the Mann–Whitney U test. Results The objective response rate was 90%, and the CR rate was 50%. CR status strongly predicted superior 2 years overall survival, locoregional control, and progression-free survival (all p < 0.05). However, no significant differences were observed between the CR and non-CR groups for tumor SUVmax, uniform model doses, or individual model doses (all p > 0.05). Conclusion 1 ⁸F-BPA PET SUVmax and the conventional individual model did not demonstrate a statistically significant association with CR in patients with HNC after accelerator-based BNCT. These findings question the utility of tumor SUVmax-based dosimetry, suggesting that current models require refinement.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Correlation of tumor maximum standardized uptake value from 18F-BPA PET and boron neutron capture therapy tumor dose with treatment outcomes in head and neck cancer: a retrospective analysis — Science Skim