Correlation of tumor maximum standardized uptake value from 18F-BPA PET and boron neutron capture therapy tumor dose with treatment outcomes in head and neck cancer: a retrospective analysis
Yuki Yoshino, Satoshi Takeno, Teruhito Aihara, Kayako Isohashi, Naonori Hu, Yasukazu Kanai, Akinori Sasaki, Mai Nojiri,
Kyoto Prefectural University · Osaka Medical and Pharmaceutical University
Key points
From the paper's conclusion- We investigated the correlation of 1 ⁸F-BPA PET SUVmax and individual model doses with treatment response.
Abstract
Abstract Purpose Boron neutron capture therapy (BNCT) dose planning conventionally uses a tumor-to-blood (T/B) ratio derived from the tumor maximum standardized uptake value (SUVmax) of fluorine-18-labeled 4-borono-L-phenylalanine ( 1 ⁸F-BPA) positron emission tomography (PET) (individual model). It remains unclear whether tumor SUVmax or individual model doses predict outcomes in accelerator-based BNCT for head and neck cancer (HNC). We investigated the correlation of 1 ⁸F-BPA PET SUVmax and individual model doses with treatment response. Materials and methods We retrospectively analyzed 30 patients with HNC treated with accelerator-based BNCT (2020–2021). The Kaplan–Meier method was used for survival analysis. Dose parameters (Dmax, Dmin, and D80%) were calculated using the uniform model (T/B = 2.5) and the individual model (T/B = Tumor SUVmax/Blood-pool SUV). Correlations between tumor SUVmax or dose parameters and best treatment response [complete response (CR) vs. non-CR] were evaluated using the Mann–Whitney U test. Results The objective response rate was 90%, and the CR rate was 50%. CR status strongly predicted superior 2 years overall survival, locoregional control, and progression-free survival (all p < 0.05). However, no significant differences were observed between the CR and non-CR groups for tumor SUVmax, uniform model doses, or individual model doses (all p > 0.05). Conclusion 1 ⁸F-BPA PET SUVmax and the conventional individual model did not demonstrate a statistically significant association with CR in patients with HNC after accelerator-based BNCT. These findings question the utility of tumor SUVmax-based dosimetry, suggesting that current models require refinement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Boron Neutron Capture Therapy at a Crossroads: Translational Gap and Emerging Delivery AgentsChemistry - A European Journal · 2026
- A LAT1-selective PET tracer, 5-[¹⁸F]F-αMe-3BPA, as a companion to its structurally matched ¹⁰B analog in boron neutron capture therapyEuropean Journal of Nuclear Medicine and Molecular Imaging · 2025
- Boron Neutron Capture Therapy: A Technology-Driven RenaissanceCancers · 2026
- Preliminary clinical outcomes of accelerator-based BNCT for head and neck cancer.Auris, nasus, larynx · 2026
- Advances in Clinical Trials of Boron Neutron Capture TherapyResearch · 2025
- Laryngeal Preservation with Boron Neutron Capture Therapy for Metachronous Second Primary Head and Neck Cancer in the Pharyngolaryngeal Region Within a Previously Irradiated Field.Cancers · 2026