  • The results support frequency band-level augmentation as a neurophysiologically informed approach to EEG spectrogram classification. Ablation indicated distinct module contributions, and Grad-CAM highlighted frequency-specific regions consistent with ADHD neurophysiology. This framework may support EEG-based computer-aided screening, although external validation is required before clinical use.

Abstract

OBJECTIVE: This study developed neurophysiologically informed data augmentation strategies to improve electroencephalogram (EEG)-based deep learning classification of attention deficit hyperactivity disorder (ADHD) in children with limited labeled EEG data. ADHD affects approximately 8.0% of children and adolescents worldwide, or about 129 million individuals aged 5-19 years. Clinical diagnosis relies largely on behavioral observations; EEG provides objective biomarkers, but conventional image augmentation may not preserve disease-relevant neural oscillation patterns. METHODS: We introduced band-shuffle augmentation, which exchanges selected spectral content between samples within the same diagnostic class at the level of canonical EEG frequency bands. The method was evaluated through systematic architecture optimization, augmentation experiments, and integration into an adaptive multistrategy training pipeline. RESULTS: Band-shuffle augmentation achieved 75.05% validation accuracy, 75.76% F1 score, 75.30% sensitivity, and 74.56% specificity, exceeding the 74.32% accuracy of traditional computer vision augmentation. The integrated multistrategy framework achieved 77.47% validation accuracy and 0.8414 AUC, improving accuracy by 27.0% over the 60.99% MobileNetV2 baseline and by 4.2% over conventional augmentation. CONCLUSION: The results support frequency band-level augmentation as a neurophysiologically informed approach to EEG spectrogram classification. Ablation indicated distinct module contributions, and Grad-CAM highlighted frequency-specific regions consistent with ADHD neurophysiology. This framework may support EEG-based computer-aided screening, although external validation is required before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers