Automated framework for volumetric musculoskeletal segmentation and assessment of torso CT images in large-scale databases.
Sanaa Amina Gourine, Mazen Soufi, Yoshito Otake, Yuto Masaki, Yoko Murakami, Yukihiro Nagatani, Yoshiyuki Watanabe, Keisuke Uemura,
Division of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, 630-0192, Japan. gourine.sanaa_amina.gt9@is.naist.jp. · Division of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, 630-0192, Japan. msoufi@miyazaki-u.ac.jp.
Key points
From the paper's conclusion- We developed and validated an automated framework for volumetric segmentation and analysis of 21 torso structures. By integrating the predictive uncertainty, our method ensures reliable biomarker extraction in large-scale studies. Our findings revealed significant age- and sex-related trends in muscle density and volume, demonstrating the framework's potential as a scalable solution for automated MSK assessment in CT images.
Abstract
PURPOSE: Automated assessment of musculoskeletal (MSK) structures in large-scale torso CT databases remains challenging due to high anatomical complexity and imaging variability. This study proposes an automated framework for the volumetric segmentation and quantitative analysis of 19 torso muscles and two fat structures, validating the integration of predictive uncertainty as a quality control tool for large-scale analysis. METHODS: We validated two model architectures incorporating structure-wise predictive uncertainty: a 2D Bayesian UNet (2D BUNet) using Monte-Carlo dropout sampling and a 3D patch-based nnUNet utilizing entropy of prediction probabilities, named 3D MSKSegmenter (3DMS). We additionally compared the accuracy against TotalSegmentator (TS), a state-of-the-art public whole body segmentation model. The predictive uncertainty was employed as a quality control tool to filter reliable cases for downstream feature analysis, and the investigation of structure volume and density [mean Hounsfield Units (HU)] associations with age and sex across a large-scale database. RESULTS: The segmentation accuracy was validated via fivefold cross-validation on 20 manually labeled CT images. 3DMS achieved a superior average Dice coefficient (DC) of 0.89 ± 0.03 compared with 2D BUNet and TS (p < 0.001). Strong negative correlations between the predictive uncertainty and DC (- 0.870 for 3DMS and - 0.955 for 2D BUNet) were observed. Furthermore, an external test on a single-institutional database of approximately 1200 patients confirmed the robustness of our framework for large-scale analysis. CONCLUSIONS: We developed and validated an automated framework for volumetric segmentation and analysis of 21 torso structures. By integrating the predictive uncertainty, our method ensures reliable biomarker extraction in large-scale studies. Our findings revealed significant age- and sex-related trends in muscle density and volume, demonstrating the framework's potential as a scalable solution for automated MSK assessment in CT images.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated thigh muscle segmentation using foundation models: validation and impact of segmentation quality.European radiology experimental · 2026
- Deep learning segmentation with uncertainty quantification for spinal tuberculosis on fat-suppressed T2-weighted MRI.Frontiers in physiology · 2026
- FocusedON-BC: A Robust Deep Learning Framework for Automated Body Composition AssessmentNutrients · 2026
- AutoLMISeg: A Fully Automated Pipeline for 3D Lumbar Muscle Volumetry and Densitometry on CT - Technical Validation Against an Operator-Driven Workflow.Journal of imaging informatics in medicine · 2026
- Deep-learning body composition analysis of routine CT robust to scan range, slice order and contrast phasemedRxiv · 2026
- Arm and shoulder muscle segmentation in axial MRI with UNet deep learning model.Journal of biomechanics · 2026