From cryogenic ball milling to aqueous dispersion: preparation of fragment-like polyethylene and polystyrene microplastic test materials.
Adnan Irshad, Rasoul Khayyam Nekouei, Rehan Khalid, Veena Sahajwalla
Centre for Sustainable Materials Research and Technology, SMaRT@UNSW, School of Materials Science and Engineering, University of New South Wales, UNSW, Hilmer Building, Sydney, NSW, 2052, Australia. a.irshad@unsw.edu.au. · Centre for Sustainable Materials Research and Technology, SMaRT@UNSW, School of Materials Science and Engineering, University of New South Wales, UNSW, Hilmer Building, Sydney, NSW, 2052, Australia.
Key points
From the paper's conclusion- These findings guide the selection of milling conditions and dispersing agents for preparing fragment-like MP suspensions for laboratory studies.
Abstract
Preparation of reproducible microplastic (MP) test materials remains a key challenge in fate, toxicity, and removal studies. This study developed a facile cryogenic ball-milling and surfactant-assisted dispersion workflow to produce fragment-like polyethylene (PE) and polystyrene (PS) MP test materials. Milling was optimised by varying feed mass, milling time, bead size, bead number, and cycle configuration. The lowest PS Dv90 was 244 µm, achieved using 1-g feed, single 25-mm bead and 5 min of milling time. Optimised conditions for PE (0.25 g of feed with five 10-mm beads milled for 15 min) reduced Dv90 from 235 to 59 µm. MPs produced under the respective optimised milling conditions were tested in 0.02% (w/v) aqueous solutions of Tween 80, Triton X-405, polyvinyl alcohol (PVA) and polyethylene glycol (PEG). Suspension behaviour was assessed by 24-h visual observation and 2-h turbidity measurements, supported by contact-angle and FTIR analyses. Among the tested surfactants, Tween 80 produced the most effective dispersion and reduced the contact angles from 115° to 84° (PE) and 88° to 57° (PS). Under static conditions, visible suspension persisted for at least 24 h for PE and more than 3 h for PS. The observed behaviour is consistent with improved interfacial wetting and possible steric stabilisation at the MP-water interface. FTIR spectra of the recovered, rinsed MPs retained the characteristic polymer bands, with no detectable chemical modification. These findings guide the selection of milling conditions and dispersing agents for preparing fragment-like MP suspensions for laboratory studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Solvent-Free Bubbling Extraction Mass Spectrometry for Ultrasensitive, Size-Independent Detection of Microplastics in Water.Analytical chemistry · 2026
- Microplastic removal from artificially contaminated river sand using agglomeration-micro-flotation: Preliminary experimentsIOP Conference Series: Earth and Environmental Science · 2026
- Eco-corona chemistry and metal fractionation in polyethylene microplastics: A dual-objective approach to ultrasound-assisted extraction.Environmental pollution (Barking, Essex : 1987) · 2026
- UV–Photocatalytic Degradation of Polyethylene and Polystyrene Microplastics in Water: Rapid Spectroscopic and Thermal Metrics for Early OxidationMicroplastics · 2026
- A simple and reliable method for the qualitative and quantitative analysis of nano- and microplastics in organs for controlled preclinical studiesParticle and Fibre Toxicology · 2026
- Soluble extracellular polymeric substances and microplastics: Exposure-response and circular reuse for removalChemosphere · 2025