Assessment of groundwater resource vulnerability at a petroleum hydrocarbon contaminated site based on geoelectrical and hydrochemical techniques.
Kehinde Ishola, Olawale Olatinsu, Olufunmilayo Omotola, Idris Olasupo, Amidu Ige-Adeyeye, Ibrahim Adeosun
Department of Geosciences, University of Lagos, Akoka, Lagos, Nigeria. kishola@unilag.edu.ng. · Department of Physics, University of Lagos, Akoka, Lagos, Nigeria.
Key points
From the paper's conclusion- Hence, this confirms the community's growing concern as regards groundwater contamination status resulting from hydrocarbon leaks caused by ruptured and vandalised pipelines.
Abstract
A site investigation carried out within the Baruwa community, Lagos, Nigeria, with the aim of mapping and evaluating hydrocarbon leakages from vandalised buried pipelines contaminating soil/groundwater. Six 2-D electrical resistivity imaging and 30 vertical electrical soundings (VES) measurements were carried out, on the survey lines. Water samples from hand-dug wells and boreholes were collected for the physico-chemical analysis. The total computed longitudinal conductance was used to determine the aquifer protective capacity rating while the geoelectrical resistivity constrained with borehole logs delineated four geoelectric layers: topsoil (lateritic), sandy clay, clayey sand, and sand. For the sampled water from the observed wells, the results of the physico-chemical analysis revealed that BH-1 to BH-7, the pH, chloride (Cl-), BOD, TSS, and heavy metals values are higher than a maximum acceptable limit of NESREA (2009). The implication of these values is that the aquifer systems could have been contaminated with hydrocarbons. On the contrary, the results from the control boreholes, BH-8 and BH-9, are well below the acceptable limits. The overburden protective capacity evaluated revealed that the geologic units overlying the aquifer units are less effective in their capability to safeguard the aquifer systems. The aquifer protective capacity ranges from poor, weak, to moderate across the study area. The correlation matrix values of greater than 0.6 indicated strong positive linear relationships for some of the water quality variables compared. Hence, this confirms the community's growing concern as regards groundwater contamination status resulting from hydrocarbon leaks caused by ruptured and vandalised pipelines.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of Geoelectric and Hydrogeological Methods in Delineation of Aquifer Potential and Protective Capacity in Parts of Asaba Metropolis, Niger Delta Region of NigeriaNigerian Journal of Physics · 2026
- Assessment of Seawater Intrusion in Coastal Aquifers Using Integrated Hydrochemical Indices and Geophysical Techniques: A Case Study of the Niger Delta, NigeriaAsian Journal of Applied Chemistry Research · 2026
- Geoelectric and vulnerability assessment of aquifers in recharge, discharge and intermediate zones of Southwestern Nigeria.Environmental geochemistry and health · 2026
- Geoelectrical characterization of aquifer systems for sustainable WASH infrastructure development in coastal Akwa Ibom State, NigeriaDiscover Water · 2026
- Hydro-geochemical, geospatial, and geophysical assessment of contaminant dispersion and health risks at Ilokun municipal dumpsite, Ado Ekiti, southwest NigeriaDiscover Environment · 2026
- Hydrochemical Characterisation, Heavy Metal Pollution, and Human Health Risk Assessment of Groundwater in Selected Coastal Communities of the Niger Delta, NigeriaIconic Research and Engineering Journals · 2026