High-Sensitivity Hydrogen Gas Permeation: System Development, Sample Preparation, and Influence of Testing Variables.
R Li, A Zafra, Z D Harris, E Martínez-Pañeda
Department of Engineering Science, University of Oxford, Oxford, OX1 3PJ UK. · Mechanical Engineering and Materials Science Department, University of Pittsburgh, Pittsburgh, PA 15261 USA.
Key points
From the paper's conclusion- The developed high-sensitivity permeation system resolves hydrogen fluxes as low as 1.98 × 10 - 9 mol/(m 2 · s) and provides a robust platform for investigating surface, mechanical and environmental effects on hydrogen permeation under realistic service conditions.
Abstract
BACKGROUND: There is a need to develop quantitative, high-resolution hydrogen gas (H 2 ) permeation techniques to provide a better understanding of hydrogen-material interactions, from hydrogen uptake and diffusion to embrittlement. OBJECTIVE: This study aims to develop and validate a high-sensitivity H 2 permeation system, which is then leveraged to systematically quantify the influence of surface condition and key testing variables (surface oxides, residual gas impurities, pressure, and temperature) on hydrogen permeation. METHODS: A gas permeation system capable of operating at pressures up to 50 bar and temperatures up to 250 ∘ C was developed, incorporating high-sensitivity mass spectrometric detection and controlled surface preparation protocols. Permeation transients were analysed in a model material (annealed pure Fe) to determine hydrogen diffusivity and permeability under systematically varied surface states, oxygen contents, pressures and temperatures. RESULTS: Surface oxides are shown to play a dominant role in controlling hydrogen permeation at room temperature. The presence of oxide layers can severely hinder or completely suppress hydrogen uptake, with measurable permeation requiring oxide removal via pickling and Pd coating on both surfaces, or activation through hydrogen-assisted reduction at elevated temperature. Residual oxygen present prior to hydrogen exposure further reduces permeability by modifying surface boundary conditions, indicating strongly surface-controlled kinetics. Under optimised surface conditions, hydrogen transport follows bulk diffusion-controlled behaviour, with steady-state flux obeying Sieverts' law at 25 ∘ C (1-5 bar) and diffusivity and permeability exhibiting Arrhenius behaviour between 25 and 150 ∘ C at 5 bar, indicating bulk diffusion-controlled transport. CONCLUSIONS: The developed high-sensitivity permeation system resolves hydrogen fluxes as low as 1.98 × 10 - 9 mol/(m 2 · s) and provides a robust platform for investigating surface, mechanical and environmental effects on hydrogen permeation under realistic service conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High sensitivity SAW hydrogen gas sensor based on thermal conductivity effectMicrosystems & Nanoengineering · 2026
- Hollow specimen method for tensile tests in high-pressure hydrogen gas: The role of strain rate and surface qualityMRS Bulletin · 2026
- Gaseous hydrogen permeation behavior of the base metal and weld metal of X42 and X52 pipeline steels under different hydrogen pressureCorrosion Science · 2025
- The role of pearlite lamellae spacing on hydrogen permeationInternational Journal of Hydrogen Energy · 2026
- Hydrogen Permeation Behavior of Locally Reinforced Type IV Hydrogen Storage VesselsPolymers · 2026
- Corrosion Product Films as Natural Barriers for Hydrogen Energy Pipelines: Structure-Permeation Correlations.Small (Weinheim an der Bergstrasse, Germany) · 2026