A randomised controlled crossover trial comparing two mandibular repositioning appliances for treatment of moderate obstructive sleep apnoea.

Jorden Blok, Zoë Van Houtvinck, Susie Klerkx, Guido Heijsters, Joeri Meyns

Oral and Maxillofacial Surgery department, Ziekenhuis Oost-Limburg (ZOL), Genk, 3600, Belgium. jordenblok@hotmail.com. · Faculty of Medicine and Life Sciences, LCRC-MHU, Hasselt University, Diepenbeek, 3590, Belgium.

Randomised

Key points

From the paper's conclusion
  • Both appliances were associated with reductions in AHI. The non-prespecified between-appliance comparison detected no statistically significant difference and does not establish equivalence. Complete confounding between period and measurement methodology, together with insufficient adherence, titration and adverse-event data, limits conclusions about the overall comparative merits of the appliances.

Abstract

PURPOSE: To compare two custom-made bi-block mandibular repositioning appliances, the SomnoDent® Flex and the OrthoApnea NOA®, in adults with moderate obstructive sleep apnoea (OSA). METHODS: Randomised two-period, two-sequence crossover trial at a single centre (Genk, Belgium). Adults with polysomnography-confirmed AHI 5-30 events/h were eligible; all enrolled had moderate OSA (AHI 15.1-29.7). Participants were randomised 1:1 to SomnoDent® Flex-NOA® or the reverse sequence, each worn for three months with a two-week washout. Participants and clinicians were unblinded; outcome scorers were blinded to appliance. The registered primary outcome was the change in AHI from baseline for each appliance. The between-appliance difference in post-treatment AHI was assessed in a non-prespecified principal comparative analysis using linear mixed-effects models with appliance, period and sequence as fixed effects. RESULTS: Sixteen participants were randomised, eight per sequence, and all were analysed. Median AHI fell from 17.6 events/h at baseline to 3.1 with the SomnoDent® Flex and 2.3 with the NOA® (both p < 0.001 versus baseline). The between-appliance difference was + 0.16 events/h (95% CI - 2.56 to + 2.87; p = 0.904), with a period effect (+ 3.82 events/h in period 2, coinciding with the change from home polygraphy to in-laboratory polysomnography; p = 0.009). No secondary outcome differed significantly; post hoc, AHI < 5 events/h was reached in 12/16 (SomnoDent® Flex) and 10/16 (NOA®). No participant discontinued for an adverse event; adverse events were not systematically recorded. CONCLUSION: Both appliances were associated with reductions in AHI. The non-prespecified between-appliance comparison detected no statistically significant difference and does not establish equivalence. Complete confounding between period and measurement methodology, together with insufficient adherence, titration and adverse-event data, limits conclusions about the overall comparative merits of the appliances. TRIAL REGISTRATION: ClinicalTrials.gov NCT06810479, registered 5 February 2025, prior to first enrolment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers