Key points
From the paper's conclusion- Raw registered PET slices did not provide stable participant-generalizable classification of an SUVR-derived amyloid target. Participant-level separation, validated tracer quantification, demographic baselines, and external validation remain necessary before clinical interpretation.
Abstract
PURPOSE: Hybrid convolutional neural network (CNN)-transformer models are increasingly proposed for molecular imaging, but scan-level leakage and targets derived from the same image-quantification pipeline can overstate performance. We tested whether an image-only hybrid model could classify florbetapir PET amyloid positivity under participant-disjoint validation. PROCEDURES: The Dallas Lifespan Brain Study contributed 551 longitudinal PET scans from 295 participants; 152 scans (27.6%) were amyloid-positive using the released global standardized uptake value ratio (SUVR) threshold of 1.09. Raw PET volumes were rigidly registered without label access and represented by 24 axial slices. CNN-GAP, slice-transformer, and age/sex baselines were evaluated using nested five-fold stratified group cross-validation. Calibration and operating thresholds were learned only within validation partitions, and 95% confidence intervals used 2,000 participant-cluster bootstrap resamples. RESULTS: The hybrid achieved ROC-AUC 0.496 (95% CI 0.427-0.569), PR-AUC 0.274, balanced accuracy 0.490, and Matthews correlation coefficient -0.017. It did not outperform CNN-GAP (paired AUC difference -0.006, 95% CI -0.078 to 0.065) and performed below the age/sex baseline (AUC 0.690; hybrid-minus-baseline difference -0.194, 95% CI -0.287 to -0.100). Baseline-only and stable-label sensitivity analyses yielded hybrid AUCs of 0.529 and 0.502. CONCLUSIONS: Raw registered PET slices did not provide stable participant-generalizable classification of an SUVR-derived amyloid target. Participant-level separation, validated tracer quantification, demographic baselines, and external validation remain necessary before clinical interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- UNICAL: Uncertainty-Aware Multimodal Learning with MRI-Derived Synthetic Amyloid PET for Alzheimer's Disease Classification.Journal of imaging informatics in medicine · 2026
- Deep learning-based estimation of multi-tracer PET phenotypes from structural MRI for A/T/N-related analysis and progression prediction in Alzheimer's disease.NeuroImage · 2026
- Development and validation of an amyloid PET dementia of the Alzheimer's type (DAT) score.Journal of Alzheimer's disease : JAD · 2026
- NCASR-driven spectral feature recalibration for early Alzheimer's disease detectionFrontiers in Artificial Intelligence · 2026
- Multimodal Three-Class Alzheimer's Disease Classification: The MCI BottleneckarXiv · 2026
- Automated PET tracer classification in multi-site, multi-cohort studies using deep learning.EJNMMI research · 2026