MStargetR: a reproducible, containerised workflow for end-to-end targeted (MRM/SRM) mass spectrometry data processing in R.
Harrison Szemray, Vimalnath Nambiar, Dana Hicks, Samantha Lodge, Julien Wist, Nathan G Lawler, Luke Whiley
Centre for Computational and Systems Medicine, Health Futures Institute, Murdoch University, Perth, WA, Australia. · Centre for Computational and Systems Medicine, Health Futures Institute, Murdoch University, Perth, WA, Australia. luke.whiley@curtin.edu.au.
Key points
From the paper's conclusion- MStargetR delivers automated batch processing, auditable peak review, and a documented QC layer in a single reproducible pipeline, supporting FAIR-aligned targeted metabolomics.
Abstract
INTRODUCTION: Targeted metabolic phenotyping by liquid chromatography-tandem mass spectrometry (LC-MS/MS) relies on a fragmented toolchain of proprietary vendor formats, manual integration steps, and ad hoc quality-control (QC) scripts, introducing user- and laboratory-level variation that undermines reproducibility and confounds cross-laboratory and retrospective comparison. OBJECTIVES: To provide an open-source, R-native workflow for targeted multiple reaction monitoring (MRM/SRM) mass spectrometry data that consolidates vendor file conversion, peak integration, and QC reporting into a single reproducible pipeline while preserving auditable, human-in-the-loop peak review. METHODS: MStargetR builds on msConvert and Skyline through three modules: msConvertR (vendor-to-mzML conversion), PeakForgeR (peak boundary optimisation and automated peak integration executed through Skyline), and qcCheckR (normalisation, concentration calculation, signal and batch correction, and reporting). Additionally, MStargetR has a standalone correction module and a Shiny graphical user interface. Third-party tools are pinned in version-controlled Docker images (with Apptainer support for high-performance computing), and each analytical plate emits a fully populated sky document for inspection and reimport. RESULTS: Applied to a published targeted lipidomics dataset of 128 human plasma samples targeting 1,161 lipid species, MStargetR processed all samples end-to-end, recovering all 1,161 targeted lipid features, 949 of which (81.7%) were detected and returned RSD < 30% across replicated long-term reference QCs. Analysis scaled linearly to 4,200 samples, averaging 4.1 s per sample. CONCLUSION: MStargetR delivers automated batch processing, auditable peak review, and a documented QC layer in a single reproducible pipeline, supporting FAIR-aligned targeted metabolomics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MRM Processor: An Integrated Workflow for Automated MRM Data Processing via Relative Retention Time Correction.Analytical chemistry · 2026
- Comprehensive LC-MS Metabolomics Data Processing with notame R/Bioconductor Package.Methods in molecular biology (Clifton, N.J.) · 2026
- MetaboRx: R Shiny application for quality assessment and preprocessing of mass spectrometry-based metabolomics data.bioRxiv : the preprint server for biology · 2026
- xcms in Peak Form: Now Anchoring a Complete Metabolomics Data Preprocessing and Analysis Software EcosystemAnalytical Chemistry · 2025
- msiFlow 2.0: Extending Mass Spectrometry Imaging Workflows with Mass Recalibration, Annotation, Batch Correction, and Visual Quality ControlbioRxiv · 2026
- LC-MS Data Processing Using OpenMS.Methods in molecular biology (Clifton, N.J.) · 2026