World journal of microbiology & biotechnology

Triple-agent detection: a one-tube internally controlled hydrolysis probe based real-time PCR assay for the simultaneous detection of Yersinia pestis, Bacillus anthracis and Francisella tularensis in environmental and clinical matrices.

Suchetna Singh, Moumita Paul, Pranjal Kumar Yadav, Sanjay Kumar, Duraipandian Thavaselvam

Biodetector Development Test and Evaluation Division, Defence Research & Development Establishment, Defence Research and Development Organization, Jhansi Road, Gwalior, Madhya Pradesh, 474 002, India. · Biodetector Development Test and Evaluation Division, Defence Research & Development Establishment, Defence Research and Development Organization, Jhansi Road, Gwalior, Madhya Pradesh, 474 002, India. drsanjay.drde@gov.in.

Key points

From the paper's conclusion
  • Therefore, in the present study, a highly sensitive and specific hydrolysis probe-based real-time PCR assay was developed for simultaneous detection of Y. pestis, B. anthracis, and F. tularensis.

Abstract

Yersinia pestis, Bacillus anthracis, and Francisella tularensis, causative agents of plague, anthrax, and tularaemia, are high-priority category A bio-warfare agents, characterized by their high pathogenicity, ease of dissemination, and high mortality rates. The possibility of the intentional or unintentional presence of these pathogenic microorganisms in the environment, along with related and unrelated non-pathogenic microbes, underscores the importance of reliable, robust, and unambiguous strategies for detecting such low-probability, high-consequence pathogens with good sensitivity. Therefore, in the present study, a highly sensitive and specific hydrolysis probe-based real-time PCR assay was developed for simultaneous detection of Y. pestis, B. anthracis, and F. tularensis. The assay demonstrated high specificity when evaluated using closely related and non-related bacterial agents, with analytical sensitivity in the range of 5-6.3 GE copies/qPCR reaction. The performance of the developed assay was also evaluated in spiked clinical and environmental matrices, along with suitable nucleic acid extraction and amplification controls. The LOD in environmental matrices was found to be 400-4000 CFU/gm of soil and 10 CFU/mL of water, along with consistent amplification of cry1 gene of Bacillus thuringiensis spiked as extraction and amplification control. In clinical matrix, the detection limit was determined to be 100-1000 CFU/mL of human blood with consistent amplification of RNaseP gene as extraction and amplification control. The findings of the present study highlight the utility of the developed assay in highly sensitive and specific detection of three fatal biological agents in both public health and bio-threat scenarios.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers