Soil and Water Contamination by Perfluoroalkyl Acids (PFAAs) at Fire Outbreak Sites in Ghana: Distribution and Screening-level Risk Assessment
Bernard Barnor, Christopher Curtis, Kriveshini Pillay, Albert Eshun, David Essumang
Key points
From the paper's conclusion- The findings therefore provide preliminary baseline evidence of spatially heterogeneous PFOA/PFOS occurrence and support expanded analyte suites, seasonal and groundwater monitoring, source apportionment, biomonitoring, and Ghana-specific exposure assessment.
Abstract
Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants of concern because of their mobility, persistence, bioaccumulation potential, and possible adverse health effects. In this study, only two legacy perfluoroalkyl acids (PFAAs) that include perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) were quantified. Fire-outbreak locations are potential points of release because firefighting foams, thermally affected PFAS-containing materials, industrial activities, wastewater, landfill leachate, and atmospheric deposition can contribute target PFAAs to surrounding soil and water. To our knowledge, this study provides the first field investigation of PFOA and PFOS at documented fire-outbreak sites in Africa. Across 18 fire-affected soil sites, PFOA and PFOS ranged from non-detectable to 5.72 ng/g dw and non-detectable to 10.80 ng/g dw, respectively; lower-bound site means (non-detects assigned zero) were 1.12 and 1.03 ng/g dw. Among seven surface-water sites, PFOA was detected at 5/7 sites and PFOS at 4/7 sites, with ranges of non-detectable–0.793 ng/L and non-detectable–13.50 ng/L and lower-bound means of 0.357 and 2.17 ng/L, respectively. One shallow hand-dug well (WR 3W), interpreted separately from surface water, contained 5.14 ng/L PFOA and non-detectable PFOS. Using updated U.S. EPA 2024 oral reference doses in a deterministic screening model, Hazard Index (HI) exceeded 1 at one surface-water site (GR 6W, driven by PFOS) and at WR 3W (driven by PFOA), while other surface-water HIs were below 1. These Hazard Quotient (HQ)/HI values are screening indicators rather than predictions of disease and depend strongly on intake, body weight, exposure duration, treatment, and benchmark selection. Comparison with the U.S. EPA 4.0 ng/L drinking-water Maximum Contaminant Levels (MCLs) is contextual rather than a compliance determination because most samples were untreated environmental waters. The EU 0.10 µg/L 'Sum of PFAS' parametric value cannot be fully assessed because only two of the 20 listed PFAS were measured, and WHO has not finalized PFOA/PFOS guideline values. The findings therefore provide preliminary baseline evidence of spatially heterogeneous PFOA/PFOS occurrence and support expanded analyte suites, seasonal and groundwater monitoring, source apportionment, biomonitoring, and Ghana-specific exposure assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigation of perfluoroalkyl acid contamination hotspots in South Africa: a case study of fire outbreak sitesWater SA · 2026
- Dynamics of PFAS transport in the unsaturated zone: Insight from long-term monitoring of an AFFF-contaminated site.Journal of hazardous materials · 2026
- PFAS contamination and risk assessment at an AFFF production site in China: Signatures of fluorosurfactant feedstocks.Environmental pollution (Barking, Essex : 1987) · 2026
- Capturing the Organic Fluorine in Aqueous Film-Forming Foam (AFFF)-Impacted Groundwater: Suspect Screening, Extractable Organofluorine, and the Total Oxidizable Precursor Assay.Environmental science & technology · 2026
- Pollution characteristics, source analysis and risk assessment of perfluoroalkyl and polyfluoroalkyl substances of Kui River.Environmental toxicology and chemistry · 2026
- Tracking PFAS across Environmental Media Surrounding Fluorochemical Industrial Park: Insights from Nontarget Analysis and Risk AssessmentEnvironmental Science & Technology · 2026