In-Flight Self-Calibration of the STIX Grid Transmission.
Paolo Massa, Anna Volpara, Muriel Zoë Stiefel, Erhan Bilgili, Maik Degen, Olivier Limousin, Gordon J Hurford, Säm Krucker
University of Applied Sciences and Arts Northwestern Switzerland, Bahnhofstrasse 6, 5210 Windisch, Switzerland. · MIDA, Dipartimento di Matematica, Università di Genova, via Dodecaneso 35, I-16146 Genova, Italy.
Key points
From the paper's conclusion- In this work, we describe an in-flight self-calibration procedure of the STIX grid transmission below 20 keV.
Abstract
The Spectrometer/Telescope for Imaging X-rays (STIX) on board Solar Orbiter provides imaging information on the X-ray sources in solar flares by modulating the emitted radiation with pairs of grids made of stacked tungsten layers. Optical measurements of the grids were taken on the ground and utilized to derive an initial model for the grid transmission. In this work, we describe an in-flight self-calibration procedure of the STIX grid transmission below 20 keV. This technique utilizes fully-illuminated pixels of the STIX Coarse Flare Locator (CFL) as a total flux monitor. The results show that the newly established transmission is lower than what was derived from the optical measurements. This is due to imperfections of the tungsten layers which reduce the effective slit width. Pre-flight optical measurements only measure the outer layers leaving these imperfections undetected. Using the new calibration, the photon spectra derived from individual sub-collimators are consistent within ∼ 2% between 8 and 20 keV. While fitted flare temperatures do not change with the new calibration, emission measure values increase by ∼ 13% compared to those obtained with the initial grid measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analytical modelling of STIX instrumental background and its application in the spectral and imaging analysisExperimental Astronomy · 2026
- Full-field and full-spectrum response efficiency calibration of x-ray grazing incidence microscope.The Review of scientific instruments · 2026
- Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparisonJournal of Astronomical Telescopes Instruments and Systems · 2025
- In-flight calibration of the Wide-field X-ray Telescope on board the Einstein ProbeAstronomy & Astrophysics · 2026
- In-flight calibration of the Lobster Eye Imager for AstronomyAstronomy and Astrophysics · 2026
- Off-axis performance characterization of hard X-ray optics for the FOXSI-4 and FOXSI-5 sounding rocket missionsarXiv · 2026