Responsiveness and minimal important change of the Dutch Adult Strabismus-20 Questionnaire (Dutch-AS-20).
Fenna Burggraaf, Hinke Marijke Jellema, Martha J Tjon-Fo-Sang, Ruth M A van Nispen, Ellen B M Elsman
The Rotterdam Eye Hospital, Rotterdam, The Netherlands. f.burggraaf@oogziekenhuis.nl. · Amsterdam UMC location Vrije Universiteit Amsterdam, Ophthalmology, Boelelaan 1117, Amsterdam, The Netherlands.
Key points
From the paper's conclusion- Both subscales of the Dutch-AS-20 are sufficiently responsive to change in strabismus-specific QoL following strabismus surgery. These findings are an important step towards the use of the Dutch AS-20 in both research and clinical practice. Future research is needed to determine a more precise MIC and individual-level statistics for both subscales, in order to improve the interpretability of change scores for both clinical and research purposes.
Abstract
PURPOSE: The Dutch Adult Strabismus-20 questionnaire (Dutch-AS-20) is a patient-reported outcome measure (PROM) developed to assess the strabismus-specific quality of life (QoL) in adult patients with strabismus in the Netherlands. This 18-item questionnaire comprises a psychosocial and visual function subscale. The aim of this prospective, multicenter, longitudinal study was to evaluate the responsiveness and determine the minimal important change (MIC) of the Dutch-AS-20 in patients undergoing strabismus surgery. METHODS: Adult patients scheduled for strabismus surgery were enrolled. The Dutch-AS-20, EQ-5D-5L, Amblyopia and Strabismus Questionnaire (A&SQ), Diplopia Questionnaire (DQ) and two global rating of change (GRC) questions were administered pre- and/or postoperatively. We used a construct approach to assess the responsiveness, testing eight pre-specified hypotheses. We determined the MIC using adjusted anchor-based predictive modelling. RESULTS: A total of 136 patients completed the questionnaires at baseline. All pre-specified hypotheses were met, indicating sufficient responsiveness of both subscales of the Dutch-AS-20. We estimated a MIC of 3.1 T-score points for the psychosocial subscale. We could not estimate the MIC for the visual function subscale due to a low correlation with the GRC question. CONCLUSION: Both subscales of the Dutch-AS-20 are sufficiently responsive to change in strabismus-specific QoL following strabismus surgery. These findings are an important step towards the use of the Dutch AS-20 in both research and clinical practice. Future research is needed to determine a more precise MIC and individual-level statistics for both subscales, in order to improve the interpretability of change scores for both clinical and research purposes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Turkish Adult Strabismus Quality of Life Questionnaire (AS-20): A Psychometric Validation Study.Turkish journal of ophthalmology · 2026
- Patient-Reported Outcome Measures for Quality of Life in Adolescent Idiopathic Scoliosis: Validity, Reliability, and Clinical Utility-A Narrative Review.Healthcare (Basel, Switzerland) · 2026
- Determining the minimal important change in patient reported outcomes for carpal tunnel syndromePM&R · 2026
- The Stanmore Limb Reconstruction Score : validation of a novel patient-reported outcome measure.Bone & joint open · 2026
- Development and Validation of the Japanese Versions of the Eye and HRQOL Modules of FACE-Q Aesthetics for Patients Who Undergo Blepharoptosis Surgery.Journal of plastic and reconstructive surgery · 2026
- Use of pre-operative SRS-22r profiles to predict clinically meaningful improvement after AIS surgery: a detailed multivariable MCID analysis in 189 patients.Spine deformity · 2026