Pharmaceutical research

Inline Raman Spectroscopy as a Process Analytical Technology Tool for Real-Time Concentration Monitoring and Mixing Endpoint Determination of an Oligonucleotide Drug Product.

Francis Kwofie, Parind M Desai, Stephanie Williams, Anderson McLeod

Drug Product Development, Drug Development and Supply, GSK R&D, 1250 S. Collegeville Road, Collegeville, PA, 19426, USA. francis.x.kwofie@gsk.com. · Drug Product Development, Drug Development and Supply, GSK R&D, 1250 S. Collegeville Road, Collegeville, PA, 19426, USA.

Key points

From the paper's conclusion
  • Inline Raman spectroscopy coupled with PLSR provided accurate, specific, and robust real-time API concentration monitoring during oligonucleotide drug product manufacturing. The approach enabled real-time monitoring and objective mixing endpoint determination and may reduce reliance on offline measurements while improving process visibility and supporting more timely progression of manufacturing operations.

Abstract

BACKGROUND: Oligonucleotide drug product manufacturing commonly relies on time-consuming offline ultraviolet-visible (UV-Vis) spectroscopy and high-performance liquid chromatography (HPLC) analyses to confirm active pharmaceutical ingredient (API) concentration during mixing, providing limited process visibility. This study evaluated inline Raman spectroscopy as a process analytical technology (PAT) tool for real-time API concentration monitoring and mixing endpoint determination during manufacture of a model antisense oligonucleotide (ASO) drug product. METHODS: A partial least squares regression (PLSR) model was developed from inline Raman spectra using offline UV-Vis reference concentrations. Accuracy, linearity, range, precision, specificity, and robustness were evaluated, including effects of stirring speed, probe depth, and reusable versus single-use Raman optics. The validated model was applied to four ASO drug product batches manufactured in a 50-L single-use mixer. RESULTS: The PLSR model demonstrated good accuracy (RMSEP = 3.47 mg/mL), good linearity (R2 = 0.994 and 0.996 for calibration and independent prediction set, respectively), and precision (maximum %RSD = 1.12%). Minimal water interference supported specificity, and consistent performance across stirring speeds, probe depths, and Raman optic configurations demonstrated robustness. The procedure generated real-time ASO API concentration profiles and successfully determined the mixing endpoint for all four batches. CONCLUSIONS: Inline Raman spectroscopy coupled with PLSR provided accurate, specific, and robust real-time API concentration monitoring during oligonucleotide drug product manufacturing. The approach enabled real-time monitoring and objective mixing endpoint determination and may reduce reliance on offline measurements while improving process visibility and supporting more timely progression of manufacturing operations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers