Nonlinear identification of jointed connections using nonlinear internal force identification method
Tahsin Ahi, Ender Ciğeroğlu, Hossein Soleimani, H. Nevzat Özgüven
Middle East Technical University
Key points
From the paper's conclusion- The results show that the proposed method is robust to measurement noise and can accurately identify the nonlinear parameters of the connection.
Abstract
Abstract This paper presents a new method for identifying the nonlinear parameters of a connection used to couple two structures. The proposed Nonlinear Internal Force Identification Method (NIFIM) calculates the nonlinear internal forces and the corresponding relative displacements at the nonlinear connections by using the measured nonlinear responses of the system in the frequency domain. The method requires the measured nonlinear frequency response functions (FRFs) of the coupled structure, as well as the FRFs of the underlying linear system. In practical jointed systems, the linear FRFs correspond to the “stuck” mode of the nonlinear dry friction elements and can be obtained experimentally under low-amplitude excitation or computed numerically. The identified nonlinear internal forces are then used to estimate the relative displacements at joint degrees of freedom, and the parameters of the nonlinearity are obtained. The proposed method eliminates the need for measurements at the connection DOFs, a benefit of the technique as it is often difficult, if not impossible, to make such measurements in many engineering applications. The formulation developed to identify the joint forces at the connections requires measurements either at a single frequency with different excitation force amplitudes or at several frequencies in a specific range with a single excitation amplitude. The paper presents three case studies based on simulated experiments to demonstrate the performance of the proposed method and its sensitivity to measurement errors. These case studies include a lumped parameter system with dry friction nonlinearity and finite element models of two beams connected by a single bolted connection, and three bolted connections. The results show that the proposed method is robust to measurement noise and can accurately identify the nonlinear parameters of the connection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Energy-based dual-phased dynamics identification for forced nonlinear vibrationsMechanical Systems and Signal Processing · 2026
- A stabilized single-sided nonlinear inverse finite element framework for large-deformation displacement field reconstructionOcean Engineering · 2026
- An Interpretable Frequency–Domain Volterra Nonlinear Feature for Bolt Damage Detection and Preload Identification in Bolted JointsApplied Sciences · 2026
- Determining The Force Transducer Parameters Algebraically Based on The Transfer Function in Frequency Domain of The Sinusoidal Dynamic Measurement SystemMeasurement Science and Technology · 2026
- Analyzing the Sensitivity, Reliability, and Classification Accuracy of Vibration-Based Metrics for Stability Assessment of Percutaneous Osseointegrated Transfemoral ImplantsJournal of Medical Devices · 2026
- Parameter identification method for nonlinear connection structures based on Bayesian optimization, physics-informed neural networkJournal of Physics: Conference Series · 2026