Fire-induced splitting failure in the bond of deformed steel bars: effect of cement type
Ahmed Ali, Éva Lublóy
Key points
From the paper's conclusion- The results show that increasing thermal exposure led to a transition from pull-out to splitting-controlled failure between 400 and 500 °C, even when relatively high peak forces were mobilized at 400 °C.
Abstract
Post-fire bond performance of reinforced concrete is commonly evaluated using residual bond strength derived from pull-out-controlled tests; however, fire-induced cracking often promotes splitting-controlled failure, which limits the bond capacity that can be effectively mobilized in practice. This study investigates the influence of cement composition on post-fire bond behavior, with particular emphasis on failure mode transition and on effective bond capacity governed by cover splitting. Four concrete mixtures with identical nominal mix proportions were considered, comprising two slag-containing cement systems (CEM II/A-S 42.5 N and CEM III/B 32.5 N-LH/SR) and two reference systems (CEM I 42.5 N and CEM II/A-LL 42.5 N). Cylindrical pull-out specimens (120 × 100 mm) with a bonded length of 30 mm were exposed to 150, 400, 500, and 800 °C following the ISO 834 fire curve, held for two hours, and air-cooled before testing. The results show that increasing thermal exposure led to a transition from pull-out to splitting-controlled failure between 400 and 500 °C, even when relatively high peak forces were mobilized at 400 °C. The stronger association between residual effective bond capacity and flexural strength than with compressive strength suggests that post-fire bond performance is strongly influenced by the cracking resistance and fracture behavior of the concrete matrix under splitting-controlled conditions. CEM III/B exhibited an effective bond retention of 97% at 150 °C, while the reference CEM II/A-LL system retained 98% and 64% at 400 and 500 °C, respectively. At 800 °C, all mixes exhibited severe degradation, with an effective bond strength of less than 7%, indicating a near-complete loss of bond strength. The results provide experimental evidence on the influence of cement type on post-fire bond behavior and failure characteristics in reinforced concrete.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Residual Mechanical Performance and Mass Loss of Heat-Cured NaOH-Activated Fly Ash/Slag and Portland Cement Mortars After Exposure to Elevated TemperaturesBuildings · 2026
- Thermal performance of brick masonry bonded by cement/geopolymer mortar: efficiency of built and repairingJournal of Thermal Analysis and Calorimetry · 2025
- Post‐Fire Mechanics of Corroded Q690 High‐Strength Steel and Influence on H‐Shaped ColumnsMaterials and Corrosion · 2026
- Thermomechanical and microstructural response of hybrid fiber-reinforced reactive powder concrete to water quenching after high-temperature exposureComposites Part A Applied Science and Manufacturing · 2026
- Mechanical and Microstructural Performance of Different Plaster Mortars Used to Protect Interior Concrete Exposed to Elevated Temperatures.Polymers · 2026
- Bond failure of corroded rebar embedded in rubberized geopolymer concrete: Experimental evaluationConstruction and Building Materials · 2026