Journal of fluorescence

Enhanced Fluorescence and Fenton-reaction in Peroxidase Nanozyme of Functionalized Fe, N, S-Carbon Dots: H₂O₂-Induced Surface Oxidation and Detection using Conventional Turn-off and Smartphone-based Colorimetric Methods.

Shaimaa Abubakr Abdalla, Shilan A Fatah, Sameera Sh Mohammed Ameen, Khalid M Omer

Department of Chemistry, College of Science, University of Charmo, Chamchamal, Kurdistan Region, 46023, Iraq. · Department of Pharmacy, Kurdistan Technical Institute, Sulaimani, KGR, 46001, Iraq.

Key points

From the paper's conclusion
  • The proposed sensor achieved low detection limits of 3.55 µM and 8.99 µM for fluorometric and smartphone-based colorimetric detection, respectively.

Abstract

Peroxidase nanozymes and fluorophores have attracted considerable attention in catalysis and luminescence-based sensing applications. In this study, novel class of iron-, nitrogen-, and sulfur-functionalized carbon dots (Fe/N/S-CDs) featuring with inherent fluorescence and peroxidase-like activity were developed successfully via a facile hydrothermal approach. The Fe/N/S-CDs displayed strong blue fluorescence under UV irradiation with a high quantum yield of 44.5%. The incorporation of Fe active centers within the carbon framework and surface structure endowed Fe/N/S-CDs with efficient peroxidase-like activity toward hydrogen peroxide (H₂O₂) through a Fenton-like reaction, producing hydroxyl radicals (•OH). The generated •OH radicals induced surface oxidation of Fe/N/S-CDs, resulting in fluorescence quenching and enabling a selective "on-off" sensing mechanism. Structural and spectroscopic analyses confirmed H₂O₂-induced surface oxidation of Fe/N/S-CDs, accompanied by increased oxygen-containing functional groups, altered electronic structure, and sustained Fe²⁺/Fe³⁺ redox cycling. Based on this strategy, a dual-mode sensing platform integrating fluorometric detection and smartphone-assisted colorimetric analysis was developed for H₂O₂ monitoring. The proposed sensor achieved low detection limits of 3.55 µM and 8.99 µM for fluorometric and smartphone-based colorimetric detection, respectively. Wide linear ranges of 4-5000 µM for fluorometric analysis and 30-1000 µM for smartphone-based detection were obtained. The practical applicability of the sensing platform was evaluated using commercial and medical H₂O₂ samples, demonstrating excellent recovery values ranging from 98.9% to 104.8% with low RSDs. The integration of functionalized Fe/N/S-CD nanozymes with smartphone-based analysis establishes a robust dual-mode sensing platform that paves the way for accessible, reliable, and real-time chemical sensing in environmental, biomedical, and food safety applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers