Metal Complex-Based Fluorescent Probe for Sensitive Determination of Citric Acid in Food Samples via a Ligand-Exchange Reaction: An Innovative and Sustainable Approach.
Rehab H Elattar, Somaia Hisham, Aya Saad Radwan, Manal A Alossaimi, Adel Ehab Ibrahim, Ahmed Emad F Abbas, Anmar Anwar Khan, Bodour S Rajab,
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt. rehabhamdy216@gmail.com. · Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Kafrelsheikh University, Kafrelsheikh, 33511, Egypt.
Key points
From the paper's conclusion- A novel, rapid, and eco-friendly spectrofluorimetric method was developed and validated for the sensitive determination of citric acid in food samples using an iron(III)salicylate metal complex as a fluorescent probe.
Abstract
A novel, rapid, and eco-friendly spectrofluorimetric method was developed and validated for the sensitive determination of citric acid in food samples using an iron(III)salicylate metal complex as a fluorescent probe. The method may involve a possible ligand-exchange process, in which citric acid preferentially coordinates with iron(III), potentially releasing free salicylate and resulting in a marked increase in fluorescence intensity at 409 nm upon excitation at 295 nm. Experimental parameters, including reagent concentration, pH, solvent type, and reaction time, were systematically optimized to maximize sensitivity. The method was validated according to ICH guidelines, showing excellent linearity over 0.2-4.0 µg/mL (r = 0.9999) and low detection and quantitation limits of 0.028 and 0.086 µg/mL, respectively. High accuracy, precision, robustness, and selectivity were achieved, with no significant interference from common food constituents. Practical applicability was demonstrated through successful determination of citric acid in juice, cola, and ice cream using the standard addition technique. Sustainability assessment using ComplexGAPI, AGSA, and MA tools indicated a favorable environmental profile, as it employs only distilled water, minimizes hazardous organic solvents, avoids heating and complex sample preparation, making it suitable for routine food analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrated Fe(III)-driven liquid-phase microextraction-spectrophotometry for selective and high-throughput detection of ethyl maltol in complex food samples.Analytical and bioanalytical chemistry · 2026
- A smartphone-integrated test strip platform based on a europium-based ratiometric fluorescent probe for on-site and visual detection of PO43- in milk.Analytical methods : advancing methods and applications · 2026
- A sensitive fluorescent probe enables rapid detection of sulfite in food samples within seconds.Analytical methods : advancing methods and applications · 2026
- Rapid fluorimetric determination of glyphosate in beer and fruit juices using a chitosan-coated magnetic-fluorescent molecularly imprinted sensor.Food chemistry · 2026
- A sodium alginate-based aggregation-induced emission fluorescent sensor for detecting nitrite in food.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Ultrasound-assisted dispersive solid-phase extraction of Ultratrace Fe(III) and Cr(III) from environmental waters using modified nanoporous MCM-41 as a novel adsorbentResults in Chemistry · 2026