Preoperative pulse rate variability and the hemodynamic response to tracheal intubation: a retrospective secondary analysis.
Gayeon Ryu, Jae Moon Choi, Byung-Moon Choi, Hangsik Shin
Department of Medical Informatics and Statistics, Brain Korea 21 Project, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. · Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Key points
From the paper's conclusion- We examined whether preoperative pulse rate variability (PRV), a photoplethysmography-derived surrogate of heart rate variability, is associated with this response.
Abstract
Individual hemodynamic responses to tracheal intubation vary considerably. We examined whether preoperative pulse rate variability (PRV), a photoplethysmography-derived surrogate of heart rate variability, is associated with this response. In this retrospective secondary analysis, 183 adults undergoing elective surgery under general anesthesia were analyzed. A 3-min photoplethysmogram was recorded in the supine, resting, unsedated state immediately before induction, and time-domain (mean pulse-to-pulse interval [mean PPI], RMSSD, and pNN50) and frequency-domain (LF power, HF power, and LF/HF) PRV indices were computed. A hemodynamic response was defined as a systolic blood pressure rise >15 mmHg, or a heart rate rise to >90 beats/min or by >30% (≥ 10% if baseline ≥90 beats/min); patients were classified as response-present or response-absent. Of 183 patients, 101 (55.2%) were response-present and 82 (44.8%) response-absent. LF/HF was higher in the response-present group (1.84 [1.32-2.60] vs 1.37 [0.78-2.44]; unadjusted P = 0.018), but no index remained significant after correction for multiple comparisons (LF/HF adjusted P = 0.109; all others adjusted P ≥ 0.301). Discrimination was limited (AUC 0.602; 95% CI 0.518-0.684). In a sensitivity analysis using a blood-pressure-only response definition, no PRV index differed significantly. After correction for multiple comparisons, no preoperative PRV index differed significantly between patients with and without a hemodynamic response to tracheal intubation. LF/HF was higher in the response-present group before correction, but the effect size was small and the discriminative performance limited. These findings do not support preoperative PRV for identifying patients at risk and are hypothesis-generating only. Trial Registration number: KCT0005840.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of the PI ratio for predicting the timing of endotracheal intubation: an observational studyBMC Anesthesiology · 2026
- Heart rate variability and baroreflex sensitivity derived from finger photoplethysmography during dynamic cerebral autoregulation assessments: Association with age, sex and time of day in healthy volunteers.Physiology international · 2026
- Intraoperative hemodynamic patterns during hypotension prediction index-guided care: a high-resolution secondary analysis of the HYT trial.Minerva anestesiologica · 2026
- Comparative study of intravenous clonidine versus fentanyl in attenuating hemodynamic response to laryngoscopy and tracheal intubationAsian Journal of Medical Sciences · 2026
- Inter-anesthesiologist Practice Variation in Vasopressor Administration for Intraoperative Hypotension: A Retrospective Cohort Study.Cureus · 2026
- Reliability and inter-device agreement of multi-site heart rate variability measurements during transcutaneous auricular vagus nerve stimulation: a prospective single-arm methodological physiological study.BMC cardiovascular disorders · 2026