A comparison between two indices derived from automated pupillometry devices.
Carlotta Bandoni, Khalil Mounir, Francesca Iannuzzi, Andrea Berardino, Fabio Tarantino, Mohammed Rabi Andaloussi, Fabio Silvio Taccone, Denise Battaglini,
Department of Anesthesia and Intensive Care, AOM Ospedale Policlinico San Martino, Genova, Italy. · Department of Surgical Intensive care, Hôpital Militaire d'Instruction Mohammed V, Rabat, Morocco.
Key points
From the paper's conclusion- To compare the performance of two commercially available automated pupillometry devices, and in particular QPI and NPi, in a cohort of neuro-critically ill patients.
Abstract
Automated pupillometry provides a standardised, quantitative, highly reproducible measurement of the pupillary light reactivity and other pupillary variables. The Neurologic pupillary index (NPi) has shown good prognostic value in patients with acute brain injury and cardiac arrest. However, few data on the comparison of NPi with a recently introduced index (quantitative pupillary index, QPI) are available. To compare the performance of two commercially available automated pupillometry devices, and in particular QPI and NPi, in a cohort of neuro-critically ill patients. Single-center observational study, including adult (> 18 years) patients admitted to a neuro-intensive care unit over a 6-month period. Pupillary reactivity was assessed in both eyes of each patient using the two pupillometers currently available, the Neuroptics NPi-300 (Neuroptics, Irvine, CA, USA) and the NeuroLight (ID-Med, Marseilles, France). A total of 73 patients were included in the final analysis, with a median age of 65 years (interquartile range [IQR] 54-77). The mean bias between the two pupillometers was 0.44 mm (95% Limit of Agreement [LoA] - 0.43 mm to 1.31 mm) for pupil diameter, 0.57% (95% LoA - 7.63% to 8.77%) for pupillary reactivity, and - 0.82 (95% LoA - 2.70 to 1.05) for NPi vs. QPI comparison. A very strong correlation was found between the two devices in terms of pupil diameter measurement (ρ = 0.91; 95% Confidence Interval [CI] 0.86 to 0.95; p < 0.0001) and pupil reactivity (ρ = 0.92; 95% CI 0.87 to 0.95; p < 0.0001). NPi and QPI were well correlated (ρ = 0.75; 95% CI, 0.62-0.84; p < 0.0001). In this cohort study, a significant statistical correlation between the measurements provided by two available pupilometers was found; however, NPi and QPI might not be clinically interchangeable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of two automated pupillometry indices in patients with acute brain injury: the prospective multicentre LYNX cohort study.Critical care (London, England) · 2026
- Comparison of bedside clinical pupillary assessment with automated pupillometry in sedated ICU patients.BMC anesthesiology · 2026
- Longitudinal Quantitative Pupillometry and Its Association with the Best Documented Level of Consciousness During ICU Hospitalization: A Single-Center Retrospective Cohort Study.Diagnostics (Basel, Switzerland) · 2026
- Neurological Pupil Index and Outcome After Cardiac Arrest in Children: Single-Center, Retrospective Cohort, 2018-2023.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2026
- Automated pupillometric quantification of relative afferent pupillary defect: comparison with neutral density filter grading in unilateral/asymmetric optic neuropathy.Documenta ophthalmologica. Advances in ophthalmology · 2026
- Neurological Pupil Index and Delirium at Emergency Department Presentation: A Retrospective Analysis of Prospectively Collected Data.Journal of emergency nursing · 2026