International ophthalmology

Predicting OCT-derived retinal and choroidal thickness phenotypes in adults with diabetes using a tabular foundation model integrating ocular biometry and systemic health data.

Heesuk Kim, Joon Yul Choi, Chan Ho Lee, Seowoong Jun, Tae Keun Yoo

Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea. · Department of Biomedical Engineering, Yonsei University, Wonju, South Korea.

Observational · n=3,699

Key points

From the paper's conclusion
  • Anatomy-aware TabPFN predicted extreme OCT thickness phenotypes, particularly low SFCT, but much of the gain may reflect established axial-length-related anatomy. Clinical utility for OCT triage remains unproven and requires external validation.

Abstract

PURPOSE: To evaluate whether systemic health data and ocular biometry can predict distribution-defined central macular thickness (CMT) and subfoveal choroidal thickness (SFCT) phenotypes in adults with diabetes using a tabular foundation model. METHODS: We analyzed Korea National Health and Nutrition Examination Survey data (2017-2021). Upper- and lower-tail CMT and SFCT phenotypes were defined using 3%, 5%, and 10% cutoffs from the 2017-2019 development cohort and evaluated in the independent 2020-2021 temporal validation cohort. Systemic-only and anatomy-aware models, incorporating axial length and anterior chamber depth, were compared. Participant-grouped cross-validation prevented fellow-eye leakage. Discrimination, calibration, and incremental performance were assessed. RESULTS: Overall, Tabular Prior-Data Fitted Network (TabPFN), a tabular foundation model, demonstrated stronger predictive performance than conventional machine-learning algorithms across most phenotype prediction tasks. The CMT and SFCT cohorts comprised 3,732 and 3,699 eyes, respectively. In temporal validation, anatomy-aware TabPFN achieved area under the receiver operating characteristic curve values of 0.722 (high CMT 3%), 0.745 (low CMT 3%), 0.817 (high SFCT 3%), and 0.880 (low SFCT 3%). Adding ocular biometry significantly improved prediction of low SFCT phenotypes compared with systemic-only TabPFN (ΔAUC, 0.121-0.157; all P ≤ 0.003), but not compared with age-plus-axial-length logistic regression. Positive predictive values were low for rare phenotypes, and calibration varied across tasks. CONCLUSIONS: Anatomy-aware TabPFN predicted extreme OCT thickness phenotypes, particularly low SFCT, but much of the gain may reflect established axial-length-related anatomy. Clinical utility for OCT triage remains unproven and requires external validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers