Factors associated with ocular prosthesis motility in anophthalmic patients: a multivariable analysis.
Yoav Vardizer, Oren Tomkins-Netzer, Yinon Shapira
The Ruth and Bruch Rappaport Faculty of Medicine, Technion ‑ Israel Institute of Technology, Haifa, Israel. · The Ruth and Bruch Rappaport Faculty of Medicine, Technion ‑ Israel Institute of Technology, Haifa, Israel. yinonshapira@technion.ac.il.
Key points
From the paper's conclusion- In this study, prosthesis motility was primarily associated with socket dynamics, structural socket capacity, eyelid function, and chronicity of anophthalmia. These findings highlight the importance of multifactorial clinical assessment when evaluating prosthetic eye movement as part of visual and cosmetic rehabilitation after eye loss.
Abstract
PURPOSE: To identify the clinical, anatomical, and prosthetic factors independently associated with ocular prosthesis motility in anophthalmic patients. METHODS: This prospective cross-sectional study included 107 patients with unilateral anophthalmia wearing acrylic prostheses. Horizontal prosthesis motility was graded relative to the fellow eye by three independent masked examiners using a five-point ordinal scale. Candidate predictors associated in univariate analysis (p ≤ 0.10) were entered into blockwise multivariable regression across five domains: clinical background, socket and eyelid findings, socket motility parameters, prosthesis primary gaze alignment, and prosthesis structural dimensions. RESULTS: Independent predictors of prosthesis motility were socket temporal motility (β = 0.36, p < 0.001), time since anophthalmia (β = -0.23, p = 0.003), prosthesis primary gaze alignment (β = 0.21, p = 0.002), socket downward motility (β = 0.20, p = 0.027), inferior fornix depth (β = 0.19, p = 0.007), and levator function (β = 0.15, p = 0.042), together explaining 67% of the variance in examiner-rated prosthesis motility (adjusted R2 = 0.64). Prosthesis dimensions, demographic variables, and orbital implant status did not retain independent significance. CONCLUSION: In this study, prosthesis motility was primarily associated with socket dynamics, structural socket capacity, eyelid function, and chronicity of anophthalmia. These findings highlight the importance of multifactorial clinical assessment when evaluating prosthetic eye movement as part of visual and cosmetic rehabilitation after eye loss.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cosmetic Appearance After Eye Loss: The Role of Prosthesis Motility and Eyelid Function.Journal of clinical medicine · 2026
- A comparative assessment of ocular prostheses motility in patients with atrophia bulbi versus implanted anophthalmic sockets: A randomized controlled trial.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Twenty Years of Anophthalmic Surgery in a Tertiary Referral Center: Etiologies, Surgical Trends, and Clinical Findings.Beyoglu eye journal · 2026
- Does the material of the external ocular prosthesis matter? Clinical outcomes after enucleation with orbital implantation.International ophthalmology · 2026
- Outcomes of patients undergoing enucleation with and without postoperative conformer placement: a 12-year review.Orbit (Amsterdam, Netherlands) · 2026
- Orbital Defect Size Reflects Structural Displacement but Not Ocular Motor Dysfunction: A Cohort Study of 1084 Patients.Diagnostics (Basel, Switzerland) · 2026