International ophthalmology

Baseline OCT Biomarkers Associated with Anatomical Response and Long-Term Reinjection Burden in Diabetic Macular Edema Treated with Intravitreal Dexamethasone Implant.

Ozge Saritas, Piraye Dundar, Esra Yigit Gokpinar, Yelda Yildiz Tasci, Yasin Toklu

Department of Ophthalmology, Faculty of Medicine, Ankara Yıldırım Beyazıt University, Ankara, Turkey. ozgesaritas@aybu.edu.tr. · Department of Ophthalmology, Bilkent City Hospital, Ankara, Turkey.

Observational · n=130

Key points

From the paper's conclusion
  • Baseline OCT biomarkers were associated with both early anatomical response and long-term reinjection burden after switching to DEX. HRF, DRIL, and ELM disruption were associated with a lower likelihood of 6 month response, whereas EZ disruption and DRIL were associated with a higher 36 month reinjection burden. These prognostic associations require external validation.

Abstract

PURPOSE: To identify baseline optical coherence tomography (OCT) biomarkers associated with 6 month anatomical response and 36 month reinjection burden in anti-vascular endothelial growth factor (anti-VEGF)-pretreated eyes with diabetic macular edema (DME) switched to dexamethasone (DEX) implant. METHODS: This retrospective single-center cohort included 130 eyes (130 patients) followed for 36 months. Good 6 month anatomical response was defined as a ≥ 20% reduction in central subfield thickness (CST) with complete resolution of intraretinal and subretinal fluid, and frequent reinjection as ≥ 5 DEX implants within 36 months. Multivariable logistic regression was used (Firth penalized regression for reinjection), with a CST-independent fluid-resolution endpoint used as sensitivity analysis. RESULTS: Sixty eyes (46.2%) achieved good anatomical response. Hyperreflective foci (HRF; OR 0.12, 95% CI 0.02-0.48), disorganization of the retinal inner layers (DRIL; OR 0.16, 0.05-0.47), and external limiting membrane (ELM) disruption (OR 0.16, 0.04-0.54) were independently associated with lower odds of response (optimism-corrected AUC 0.88) and remained significant for fluid resolution. Seventy-nine eyes (60.8%) received ≥ 5 implants. Ellipsoid zone (EZ) disruption (OR 24.83, 3.73-345.08) and DRIL (OR 5.03, 1.45-20.27) were independently associated with frequent reinjection (optimism-corrected AUC 0.95). Month-6 and month-36 anatomical status agreed in 85.4% of eyes. Intraocular pressure > 25 mmHg occurred in 26.2% of eyes, all controlled medically. CONCLUSION: Baseline OCT biomarkers were associated with both early anatomical response and long-term reinjection burden after switching to DEX. HRF, DRIL, and ELM disruption were associated with a lower likelihood of 6 month response, whereas EZ disruption and DRIL were associated with a higher 36 month reinjection burden. These prognostic associations require external validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers