Ground calibration result of the wide-field X-ray telescope (WXT) onboard the Einstein probe
Huaqing Cheng, Chen Zhang, Zhixing Ling, Xiaojin Sun, Shengli Sun, Yuan Liu, Yanfeng Dai, Zhenqing Jia,
Chinese Academy of Sciences · US Night Vision (United States)
Key points
From the paper's conclusion- We report on results of the on-ground X-ray calibration of the Wide-field X-ray Telescope (WXT), built from novel lobster-eye micro-pore optics, on board the Einstein Probe (EP) satellite.
Abstract
We report on results of the on-ground X-ray calibration of the Wide-field X-ray Telescope (WXT), built from novel lobster-eye micro-pore optics, on board the Einstein Probe (EP) satellite. To fully characterize the performance and properties of the WXT instrument, a series of tests and calibrations were conducted at different levels of devices, assemblies and the complete module before the launch of EP. In this paper, we present the calibration results of three flight model modules (FM1, FM5 and FM11) obtained during their end-to-end module calibration experiments carried out at the 100-m X-ray Test Facility (100XF) of the Institute of High Energy Physics (IHEP), Chinese Academy of Sciences (CAS). Measurements of the Point Spread Function (PSF), effective area, and energy response were performed for multiple incident directions and several characteristic X-ray emission line energies. Specifically, the distributions of the PSF and effective areas are found to be roughly uniform across the FoV, in large agreement with the prediction of lobster-eye optics. Their energy-dependent behavior aligns well with theoretical predictions and Monte Carlo simulations. At $$\sim 1.25$$ keV, the full width at half maximum (FWHM) of the focal spot ranges from $$3-7$$ arcmin (with a median of $$\sim 4.2$$ arcmin) and the effective area is in range of $$\sim 2-3~\mathrm{cm^2}$$ . Noticeably, the flight model instruments demonstrate a $$\sim 1.5$$ arcmin improvement in spatial resolution over the previously launched Lobster Eye Imager for Astronomy. The properties of the complementary metal-oxide semiconductor (CMOS) sensors were also calibrated. The gain coefficients are in range of $$6.4-6.9~\mathrm{eV/DN}$$ . The energy resolutions are in range of $$\sim 120$$ to 140 eV at 1.25 keV, meeting design requirements. These calibration results have been ingested into the first version of calibration database (CALDB) and applied to the analysis of the scientific data acquired by WXT after the launch of EP.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In-flight calibration of the Wide-field X-ray Telescope on board the Einstein ProbeAstronomy & Astrophysics · 2026
- Empirical modeling and in-flight characterization of the extended point spread function for the Einstein Probe Wide-field X-ray TelescopeResearch in Astronomy and Astrophysics · 2026
- In-flight calibration of the Lobster Eye Imager for AstronomyAstronomy and Astrophysics · 2026
- Soft X‐Ray Telescopes of the Future: Trade Study of Micro‐Pore Optic Size for Imaging Dayside Magnetospheric FeaturesJournal of Geophysical Research: Space Physics · 2026
- Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparisonJournal of Astronomical Telescopes Instruments and Systems · 2025
- Fabrication of ultrahigh precision master mandrel toward sub-10 arcsec x-ray Wolter mirror for x-ray telescope.The Review of scientific instruments · 2026