Development of a Pb2+-selective potentiometric sensor for environmental monitoring of lead in water samples.
Sarmad Luqman Hasan Sheekhoo, Oguz Özbek, Onur Cem Altunoluk, Kıymet Berkil Akar, Ömer Isildak
Department of Chemistry, Faculty of Science and Arts, Tokat Gaziosmanpaşa University, Tokat, 60250, Türkiye. · Department of Molecular Biology and Genetics, Faculty of Science and Arts, Tokat Gaziosmanpaşa University, Tokat, 60250, Türkiye. oguz.ozbek@gop.edu.tr.
Key points
From the paper's conclusion- These findings demonstrate that the fabricated membrane sensor provides a simple, sensitive, selective, and cost-effective approach for the potentiometric determination of Pb2+ in environmental water samples.
Abstract
A Pb2+-selective potentiometric sensor based on a PVC membrane incorporating 5,8-dibromo-2-((furan-2-ylmethyl)amino)naphthalene-1,4-dione as a neutral ionophore was successfully fabricated and characterized. The membrane electrode exhibited excellent selectivity toward Pb2+ in the presence of various potentially interfering metal ions and displayed favorable electroanalytical performance. A Nernstian slope of 28.8 ± 1.09 mV/decade was obtained over the concentration range of 1.0 × 10⁻6-1.0 × 10⁻1 M, with a detection limit of 5.73 × 10⁻7 M. In addition, the sensor reached a stable potential within 6 s and operated reliably over the pH range of 4.0-9.0, while maintaining good repeatability throughout the measurements. SEM-EDX analysis and elemental mapping further provided evidence for the presence and distribution of Pb on the membrane surface after Pb2+ exposure, supporting the interaction of the ionophore-containing membrane with Pb2+. Its analytical applicability was verified by the determination of Pb2+ in environmental water samples, yielding satisfactory results. These findings demonstrate that the fabricated membrane sensor provides a simple, sensitive, selective, and cost-effective approach for the potentiometric determination of Pb2+ in environmental water samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Supramolecular fluorescent chemosensor with logic gate operations for Pb2+ detection in field-collected water samplesJournal of Water Process Engineering · 2026
- Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring.Sensors (Basel, Switzerland) · 2026
- Development of a Cobalt Tetra (diethoxycarbonylmethyl) phthalocyanine‐Based Benzydamine‐Selective Poly Vinyl Chloride Membrane Potentiometric SensorElectroanalysis · 2026
- Droplet-driven self-powered Pb2 + extraction from industrial wastewater.Journal of hazardous materials · 2026
- Built-in electric field-boosted attomolar Pb²⁺ sensing on carboxylated black phosphorene.Nature communications · 2026
- Development of Binary Pd@PPyC-Bi2O3 Nanocomposite Sensor for Trace-Level Detection of 2,4-Dinitrophenol in Wastewater via Linear Sweep Voltammetry.Chemistry, an Asian journal · 2026