Environmental monitoring and assessment

Long‑term trends and seasonal variability of particulate matter (PM10 and PM2.5) in Volta Redonda (RJ), Brazil: a 15‑year temporal analysis.

Bruno Cesar Silva Rocha, Jackson Porto Cardoso, Jéssica de Medeiros Soares, Libério Junio da Silva, Nivia de Mello Nascimento, Adriana Gioda, Marcelo Correa Bernardes

Graduate Program in Geochemistry, Department of Geochemistry, Fluminense Federal University (UFF), Niterói, RJ, Brazil. brurocha@gmail.com. · Graduate Program in Biosystems Engineering, Department of Agricultural and Environmental Engineering, Fluminense Federal University (UFF), Niterói, RJ, Brazil.

Key points

From the paper's conclusion
  • This study evaluated PM10 and PM2.5 concentrations from 2010 to 2024, investigating temporal trends, spatial and seasonal differences, and their relationships with meteorological variables.

Abstract

Air quality in Volta Redonda, Rio de Janeiro, Brazil, is influenced by industrial activities and meteorological conditions, but its temporal evolution and spatial variability require systematic assessment. This study evaluated PM10 and PM2.5 concentrations from 2010 to 2024, investigating temporal trends, spatial and seasonal differences, and their relationships with meteorological variables. The Mann-Kendall test and Theil-Sen estimator were applied to assess trends, Mann-Whitney tests to compare periods and seasons, Kruskal-Wallis tests to evaluate spatial differences, and Spearman correlations to assess meteorological relationships, complemented by pollution roses and concentration-weighted trajectory (CWT) analysis. Annual PM10 concentrations exceeded the World Health Organization annual guideline of 15 µg m⁻3 at all stations and in all analyzed years, while PM2.5 exceeded 5 µg m⁻3 in all years at the Volta Grande station. In 2024, 36% of PM10 measurements exceeded the national standard of 35 µg m⁻3, with annual means of 44 ± 22 µg m⁻3 at Conforto and 44 ± 12 µg m⁻3 at Siderville. No significant long-term monotonic trends were identified for PM10 or PM2.5; for PM2.5, the Theil-Sen slope was -0.346 µg m⁻3 year⁻1 (p = 0.0866). Concentrations were higher in winter than in summer for PM10 (p = 0.002) and PM2.5 (p = 0.001), while PM10 showed negative correlations with precipitation (r =  -0.66) and temperature (r =  -0.46). CWT analysis indicated potential contribution regions predominantly west and northwest of the receptor stations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers