Marine pharmaceutical monitoring with POCIS: sampling rate uncertainty, and implications for regulation.
Heidi Ahkola, Lauri Äystö, Mailis Laht, Vallo Kõrgmaa, Jukka Mehtonen, Kai Myrberg, Ljudmila Vesikko, Ville Junttila
Finnish Environment Institute (Syke), Latokartanonkaari 11, 00790, Helsinki, Finland. heidi.ahkola@syke.fi. · Finnish Environment Institute (Syke), Latokartanonkaari 11, 00790, Helsinki, Finland.
Key points
From the paper's conclusion- Altogether, 150 pharmaceuticals were analysed from passive and grab water samples, and 30 substances were discovered.
Abstract
POCIS passive samplers were deployed at differently polluted marine sites in the cities of Helsinki and Tallinn and in an open part of the Gulf of Finland. The aim was to determine baseline concentration levels for pharmaceuticals in water monitored with passive sampling techniques, which could also be applied to regulatory monitoring. That baseline concentration data method could then be applied to other sites in the Tallinn and Helsinki area to assess whether the pharmaceutical concentration is elevated or at the baseline level. Altogether, 150 pharmaceuticals were analysed from passive and grab water samples, and 30 substances were discovered. The number of pharmaceuticals detected in passive samplers (27) was higher than in grab samples (20). However, the study revealed the presence of several pharmaceuticals even from expected background sites, such as the open sea site in Gulf of Finland, implying their ubiquitous presence in the study area. The passive sampling results have been converted to TWAC with sampling rate, which is characteristic of the sampler type and studied compound. We assessed the suitability and differences of sampling rates collected from the literature, calculated from LogKOW values and estimated from field deployment results. The selection of sampling rate is essential, as it can cause 86 to 99% differences in determined TWACs. The TWAC was compared with PNEC was calculated to evaluate the potential environmental risk. There are still open questions regarding how to reconcile the passive sampling results with regulatory monitoring obligations based on grab water sampling and existing limit concentrations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrating passive and grab sampling with target and non-target analysis to profile organic contaminants in an urban South African river system.Environmental science and pollution research international · 2026
- Ecotoxicological risk and matrix-specific exposure of pharmaceutically active compounds in the Ankobra River, Ghana: evidence from paired water-sediment monitoring.Ecotoxicology (London, England) · 2026
- Pharmaceutical pollution in a wastewater-impacted coastal ecosystem.Environmental pollution (Barking, Essex : 1987) · 2026
- Tracking 45 pharmaceutical active compounds in a highly anthropogenically impacted basin in Mexico: Probabilistic ecological risk assessment.Journal of environmental management · 2026
- Multiclass Determination of Pharmaceuticals in Surface Water Samples by SPE and UHPLC-MS/MS for Environmental Risk Assessment.Molecules (Basel, Switzerland) · 2026
- From watershed to lagoon: Occurrence and ecological risk of paracetamol in the Segara Anakan coastal ecosystem.Environmental science and pollution research international · 2026